Elster Q.Sonic PLUS Specifications

General IconGeneral
TypeUltrasonic Flow Meter
CategoryMeasuring Instruments
Measurement PrincipleUltrasonic transit time
Flow RateDependent on line size
Accuracy±0.5% of reading
Communication InterfaceRS-485, Ethernet, Modbus TCP/IP, HART
Outputs4-20 mA, Pulse
Power Supply24 V DC
Protection ClassIP66/67
ApprovalsMID, OIML

Summary

Ultrasonic Flow Meter Series 6

Calibration

Outlines requirements for calibration by certified institutes for custody transfer applications.

Theory of Operation

Flow Velocity Measurement

Explains how ultrasonic pulses are used to measure gas velocity based on travel times across the pipe.

System Description

Installation and Commissioning

Installing a Meter in the Pipeline

Guides on safely handling and installing the meter according to regulations and spool piece requirements.

Wiring Instructions

Directs users to refer to specific documents for correct wiring procedures for the meter.

SPU Configuration

Advises on reading and comparing parameter settings using SonicExplorer software after installation.

Operation

Front Panel and Touch Display

Describes the interactive touch screen display and its seven touch areas for user interaction and navigation.

Diagnostics

Guides users on accessing and interpreting general and path-specific diagnostic data for troubleshooting.

Error List

Explains how to view, filter, and clear error and warning messages to manage device status.

Maintenance

Collecting and Inspecting Data

Procedures for collecting meter data for trend analysis and inspecting measured parameters like sample rate.

Exchanging Components

Instructions and precautions for replacing parts like sensors and transducers, with safety considerations.

Transducer Exchange

Specific steps and warnings for replacing the ultrasonic transducers, including depressurization requirements.

Verifying Software Versions

Component Software Verification

Steps to check software versions and checksums for meter components to ensure integrity.

User Rights and Login

MID Requirements