– Received packets–quantity of received voice packets;
– Received octets–quantity of bytes in received voice packets;
When you click the Hide FXS statistics button, generated statistics on performed calls on this port will be
deleted.
When you click the Hide all button the results of tests of all types will be removed.
5.1.4.2 The 'Status' submenu Board Parameter Status Monitoring
In the 'Status' submenu, you can monitor physical parameters: of the board and SFP modules supporting DDM
(digital diagnostics monitoring) function.
Table 'Hardware'–platform sensor parameters:
– 'Parameter'–controlled parameters;
– 'Value'–controlled parameters' values:
– Power, V - device power supply parameters:
• Vmode - subscriber unit power supply mode, V;
• Vbat - secondary supply circuit voltage, V.
Low - secondary supply circuit voltage is less than 44V, units operating in low voltage mode.
Normal - secondary supply circuit voltage is 44V<Vbat<55V, units operating in normal voltage mode.
Normal - secondary supply circuit voltage is more than 55V, units operating in high voltage mode.
– Power, V - voltage generated by inductor, V. The device contains two magneto ringing sources: first is
working with sets of 1-36, the second - with 37-72;