132 Universal Network Terminal TAU-72.IP/TAU-36.IP
CAPACITANCE NOT MEASUREDmeans that during the line resistance measurement one of the values was
lower than the minimum allowed value for line capacitance measurement (1800Ω). As a rule, this error may
be caused by a phone offhook or a wire or ground short circuit;
EXTERNAL VOLTAGE FAILUREexternal voltage measured in line wires falls outside of allowable limits (-5V -
+5V);
TEST ERRORtest is interrupted by a processor command.
Click the Hide test result button to remove test result information.
When you click the Hide all button the results of tests of all types will be removed.
Performed Call Statistics
The Get stat button located against each port allows to get the statistics on performed calls for the
specific port. Statistics form is formed by clicking on this button. To see the statistics, hover the mouse
cursor over the 'results' link located against the respective port, or open the test results window by clicking
the link:
Statecurrent port status:
offhookphone is offhook;
onhookphone is onhook;
FXO offhook FXO port is busy;
FXO onhook FXO port is availiable;
dialdialling number;
ringbacksend 'ringback' tone;
ringingsend 'ringing' tone;
talkingcall in progress;
conference3-way conference;
busysending 'busy' tone;
holdport is on hold;
testingport is in testing mode.
Call countnumber of outgoing calls from the gateway startup;
Call phonelast dialled number;
Peak jittermaximum jitter;
Lost packetsquantity of lost packets;
Transmitted packetsquantity of transferred voice packets;
Transmitted octetsquantity of bytes in transferred voice packets;