4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 A pro-
tection fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate movement warning light
12 Vdc 15 W max
12 Vdc 65 mA max
Courtesy light or
second radio channel
12 Vdc 65 mA max
gate movement warn-
ing light
Accessories power supply output
12 Vdc 300 mA max
Electric lock
12 V 15 VA
13 14 15 16 17 18 19
COM
APCH
APED
COM
STOP
FOTO
STPA
4.3- Input connections:
The control unit is supplied with jumpered normally closed inputs (STOP, PHOTO and STPA) remove the jumper from the input you are going to use.
Terminal
number
Description Function
1-2
Output for powering the electric motor 1
(pedestrian)
Output for controlling electric motor 1, 12 Vdc rated power 50 W (1 opening, 2 closing)
3-4 Output for powering the electric motor 2 Output for controlling electric motor 2, 12 Vdc rated power 50 W (3 opening, 4 closing)
5-9 Courtesy light or second radio channel
Output 12 V dc maximum load 65 mA, can be programmed as a timed output (60 sec-
onds) or second radio channel output, see parameter 34 (5= GND, 2can/ 9= + 12 V dc).
6-7 Output for electrical lock control Output for electrical lock at 12 Vac maximum 15 VA
8-9 Gate movement warning output
Gate movement warning output, flashes slowly when opening, on steady with gate
open, flashes quickly during closing and off with gate closed (8 = controlled GND, 9 =
permanent + 12 Vdc, maximum load 65 mA)
9-10 Accessories power supply output
Output 12 V dc maximum 300 mA for supplying the photocells and accessories (9 =
+ 12 Vdc, 10= GND)
11-12 Output for flashing light
Output at 12Vdc maximum load 15 W for flashing light (11 = flashing light GND, 12 = +
12 Vdc), if the automatic closing function is active, the flashing light is on steady during
the time of automatic closing.
Terminal number Description Input type
13-16 Control inputs common (permanent GND) _
14
Sequential control input, for
controlling the complete travel of the gate
Normally open
15
Sequential control input, for
controlling the pedestrian travel of the gate
Normally open
17 Input for stopping the gate Normally closed
18
Photocell input, active during
gate closing
Normally closed
19
Input for edges or internal photocell, active during
gate closing and opening
Normally closed
Motor 1 Pedestrian
Motor 2
-
+ -
-- +
Fig. 5
neutro
fase
Terra
Mains
Transformer
Phase
EN
Fig. 4