Stop button connection, normally closed contact, opening the contact causes the gate to stop and suspends the automatic closing time (when the button
is not engaged, the STOP LED should be lit), if not used then jumper between COM and STOP:
N.B. If the system has no photocells, sensitive edges or stop buttons (the FOTO, STPA and STOP inputs must be jumpered with the common, ter-
minal 13), do not activate the photo-test function.
4.9- Connecting the aerial
The 17cm rod is supplied pre-wired, to increase the range connect the aerial art. ZL43, as shown in the figure:
5 - Description of the LEDs and buttons on the card:
Abbreviation
Description
AC
Shows whether there is mains power (lit if there is mains voltage)
STPA
Displays the status of the STPA input (number 19), if not engaged the LED remains lit, if not used then jumper between terminal COM
and STPA
AP/CH
Displays the status of the AP/CH input (number 14), if not engaged the LED remains off
APED
Displays the status of the APED input (number 15), if not engaged the LED remains off
STOP
Displays the status of the STOP input (number 17), if not engaged the LED remains lit, if not used then jumper between terminal COM
and STOP
FOTO
Displays the status of the FOTO input (number 18), if not engaged the LED remains lit, if not used then jumper between terminal COM
and FOTO.
ENCM1
Displays the motor 1 encoder input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the
motor stopped.
ENCM2
Displays the motor 2 encoder input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the
motor stopped.
DISPLAY
Displays the programming menu status
Buttons in the circuit:
Abbreviation Description
AP/CH Controls opening and closing the gate
ESC Exit or go back to the lower level of the menu
DOWN
Decreases the displayed value by one unit or scrolling on the same menu level
OK
Confirms the value or moves to the top level of the menu, when pressed once while the gate is moving it shows the absorp-
tion of the electric motor M1 in Amps, when pressed 2 times while the gate is moving it shows the absorption of the electric
motor M2 in Amps
Preliminary check:
After powering up the control panel, the display shows the name of the control panel RS04, the firmware version Fxxx, 3 flashes with the words FLSH
and ENC (if there is an encoder) and then switches off. Check the LEDS for diagnosis of the inputs, LEDS, STOP, FOTO, STPA must be on.
Should one of the safety inputs (FOTO, STOP, STPA) not be used, insert a jumper between COM and the input not used.
Normally closed button
Fig. 10
Fig. 11
13 14 15 16 17 18 19
20 21
4.8- Stop button connection