4.6- Connecting sensitive edge or internal photocell
Programmable input: (when the edge or photocell is not engaged, the STPA LED must be on) the operation of this input, set as a sensitive edge,
has this effect: during opening it immediately reverses the movement for 1.5 seconds and then stops the gate, while during closing it reverses the
movement until fully open. See parameter number 06 (edge with normally closed contact set parameter 06 to value 2, edge with balancing resist-
ance 8.2 K ohms set parameter 06 to value 3), if not used make a bridge between COM. and STPA and leave parameter 06 on value 1.
Switch edge connectionResistive sensitive edge connection
8.2 KW
Fig. 8
4.7 Connecting photocells with photo-test function active
If the photo-test function is activated (the control unit checks the operation of the photocells, see parameter 08), respect the following connection (each
time the motor starts the control unit cuts off power to the transmitter of the photocell to check their operation):
COM
STPA
STPA as
internal photocell
COM
FOTO
Fig. 9
RX
+-CNCNA
+-
TX
RX1
+-CNCN
A+
-
RX2
+-CNCNA
+-
TX1 TX2
+
-
+
-
678910 11 12 13 14 15 16 17 18 195