1- Press the UP button once, the display will show LRNE
2- Conrm with the OK button, the display will show APCH
3- Press the APCH button
4- The display reads CLS2, motor M2 closes until the mechanical stop
5- After closing M2, M1 starts to close and the display shows CLS1
6- After closing M1 the display shows LOC (operates the electric lock)
7- M1 starts to open at slow speed and continues until the mechanical stop, the display will show OPN1
8- M2 starts to open at slow speed and continues until the mechanical stop, the display will show OPN2
9- M2 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS2
10- M1 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS1
11- The control panel runs a full gate leaf opening and closing cycle to save the current thresholds, the display will show 4 dots
12- After closing, the display will show END, the procedure has been successfully completed.
The reduced procedure allows saving the travel, with distances for slowing down of 30% the total travel, while the gate leaf delays are xed at 3 seconds
for opening and 6 seconds for closing.
6.2 Procedure for saving a remote control associated with button APCH:
1- Press the UP button 2 times, the display will show RAD
2- Press the OK button, the display will show 1CH (indicating that the remote control button will be saved as AP/CH of the control panel)
3- Press the OK button, 4 dots will appear on the display, indicating that the control panel is waiting for a remote control button to be tapped (timeout
10 seconds)
4- After pressing the remote control button the display will show a 4-digit number: the rst digit indicates association (1 controls the AP/CH input 2
controls the pedestrian entrance or the second channel output) the other 3 indicate the memory cell occupied by the remote control (the rst remote
control occupies cell 001, the second one cell 002), the maximum capacity is 200 remote controls To save other remote controls repeat the proce-
dure.
N.B.: The rst saved remote control congures the control panel to accept only remote controls with a rolling code or only remote controls with a xed