EasyManua.ls Logo

Elvox RS04 - Gate System Risk Assessment; Electrical Wiring Harness Guide

Elvox RS04
128 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
VIMAR group
3- Risk assessment
Before starting to install the automatic gate system it is necessary to evaluate all possible points of danger during the movement of the gate. The
figure shows some of the danger points of the swing gate.
Fig. 2
Before starting installation you need to check that there are secure mechanical stops and check the gate support system.
4- Electrical wiring harnesses
System set-up
Key
A - Linear actuator
B - Control unit
C - Flashing light
D - 2-channel radio control
E - Pair of photocells
F - Selector
G - Electrical lock
EN
2x0,5 mm
2
2x1 mm
2
3x0,5 mm
2
4x0,5 mm
2
2x0,5 mm
2
2x2,5 mm
2
+3x0,5 mm
2
(encoder)
2x2,5 mm
2
+3x0,5 mm
2
(encoder)
3x0,5 mm
2
230/120 Vac
C
F
G
A
E
E
A
D
B
Fig. 3

Table of Contents