EasyManua.ls Logo

EMAK EF 95 - Troubleshooting Performance Issues; Vibration, Movement, and Cut Quality Problems; Grass Catcher and Display Troubleshooting

EMAK EF 95
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
GB
PROBLEM POSSIBLE CAUSES SOLUTION
4. Lawn tractor is
vibrating severely.
Mower mechanism is damaged. Check mower mechanism.
(Customer service workshop)
5. Lawn tractor does
not move off.
With hydrostat drive: no travel
drive.
Move bypass lever to operating
position
6. Rough cut. Blade worn, blunt. Renew or regrind blade. Balance
reground blades! (Customer service
workshop)
Incorrect cutting height. Correct cutting height.
Engine speed too slow. Set maximum engine speed.
Driving speed too fast. Reduce driving speed.
Different tyre pressure at
wheels.
Inflate to correct air pressure.
Read off correct tyre pressure on tyre.
7. Grass catcher does
not fill up.
Cutting height set too low. Correct cutting height.
Grass is wet – it is too heavy to
be transported by air stream.
Mow at a later time when lawn has
dried out.
Blade severely worn. Change blade.
(Customer service workshop)
Grass in lawn too tall. Mow in 2 passes
1st pass: max. cutting height.
2nd pass: desired cutting height
Fabric bag blocked – does not
allow air to pass.
Clean fabric bag.
Discharge channel/mower deck
contaminated
Clean discharge channel/mower
deck.
8. Fill level display
does not respond.
Mown grass stuck to fill level
display lever.
Remove mown grass from fill level
display lever; check it can move clearly.
9. Travel drive, brake,
clutch and mower
mechanism.
Only have the check performed
in a customer service workshop!
WARNING: Do not attempt to carry out repairs without the necessary repairs and technical
expertise. Poorly executed repairs will automatically invalidate the warranty and relieve
the manufacturer of all liability.
ONLY FOR MODELS WITH DISPLAY
DISPLAY PROBLEM POSSIBLE CAUSES SOLUTION
Err 01 Seat switch ECU detects invalid status of the
seat switch
1. Switch the ignition off
and back on (position 2)
2. Apply load and release
load from seat several
times
*