Task 6: Reboot the storage processor 7
Once you have replaced the faulted memory module and returned the storage processor assembly to
the chassis, reboot the recently serviced SP to ensure that it leaves Service Mode:
1. From Unisphere, select Settings, then Service System.
2. Log in with your service password.
3. In the System Components column, select the replaced storage processor (A or B).
4. Under Service Actions, select Reboot, then Execute service action.
Note: It may take several minutes for the system to complete its reboot and return to Normal Mode.
5. Refresh your browser, or follow the on-screen instructions, to bring the software out of Service Mode
and restore full-function Unisphere.
Verify that the new memory module is recognized by your system, and operating correctly:
1. In Unisphere, click View System Health.
2. Select the storage processor in the Component list or the graphical view:
In the Component list, the memory should be marked with a status OK icon:
In the graphical view, the SP is highlighted green.
Note: If the system health monitor shows the replacement module as faulted, contact your service
provider.
Task 6: Reboot the storage processor
Task 7: Verify the operation of the new module