5
Programming the instrument
MENU / FUNCTIONS
To entering into “Selected function” keep pressed “P” key until the first green led will light on.
By pressing “P” key more times it is possible to verify/set the instrument functions. The
selected function is showed by the green led near the function menu. TO GO BACK TO THE
NORMAL OPERATING MODE PRESS “P” MORE TIMES UNTIL THE GREEN LED IS OFF.
“Point Consigne”: pH SetPoint. pH that the instrument aims to reach during the dosage. If the pH
value is close to the setted value, the peristaltic pump will not start working. If the pH value is different,
the peristaltic pump will dose proportionally until its maximum capacity (100%). We recommend to
set the “Point Consigne” between 7.2 and 7.4 (optimum pH value for swimming pool). Press “E” to
confirm. Press another key to exit from the menu.
“Securitè”: maximum time, in minutes, available to the instrument to reach the pH restoration, as set
in the “Point Consigne”. If the instrument does not reach this pH value during the maximum time, it
will enter in alarm mode (blinking display) and will stop the peristaltic pump functioning. Press “E” to
confirm. Press another key to exit from the menu.
“Manuel”: manual working mode of the peristaltic pump for a settable time (minutes, seconds) by
using “UP” and “DOWN” keys. Press “E” to confirm and wait a second before the pump starts
working. The display will show the remaining working time. At the end (display “000”) th instrument
will stop the dosage. To repeat another manual dosing cycle press “E” key, press “P” to exit from the
menu and cancel the operation.
“pH+”, “pH-”: chemical type used to restore the swimming pool pH value. Set on “bAS”, by “UP”
and “DOWN” keys, if using a “pH+” chemical. Set on “ACd” if using a “pH-” chemical. Press “E” to
confirm. Press another key to exit from the menu.
“Calibrage”: buffer solution value used for calibration. We recommend to use a “7pH” solution. See
next paragraph for calibration mode.
INSTRUMENT CALIBRATION
Prepare the buffer solution and the pH probe before enter into the calibration menu.
Connect pH probe to the instrument by the BNC connection. Remove the probe from the probe
holder and put it into the buffer solution. Wait until read value is stable, keep pressed the “P” key until
the first green led will light on. Leave the “P” key. Press “P” key 4 times: the green led near
“CALIBRAGE” function will light on. Use “UP” and “DOWN” keys to enter the buffer solution value
and press “E” to confirm. The value shown on the display is not the probe value but it is the
buffer solution value. So, it may not reach the buffer solution value.
INSTRUMENT MESSAGES
“DEF”: restore instrument default values. It may be operated by the user. Disconnect the instrument
from power supply, press “UP” and “DOWN” keys together then connect power supply again.
Release the “UP” and “DOWN” keys.
“PHL” o “PHH”: pH reading value out of range (not from 0 to 14pH).