PART NO. 37-7511003
Replaces 37-7511002
2042
1F83H-21PR (Programmable)
Installation and Operating Instructions
Heat Pump Thermostat
Battery Powered or Hardwired with Common
Thermostat Applications
Maximum
Stages
Heat/ Cool
Single Stage Compressor, Heat Pump
Systems (air source or geothermal) –
1 Stage Aux/Emergency Heat, Electric
or Gas (Dual Fuel)
2/1
Thermostat Installation
2-4
Wiring
2
Installer Menu
3-4
Using the Thermostat
5-7
Thermostat Overview
5
User Menu
6
Thermostat Operation
6
Thermostat Schedule
7
Troubleshooting
7-8
Homeowner Help Line
8
INDEX
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
Electrical Rating:
Battery Power ..................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (to 37° C)
Rated Dierentials (@ 6°F/ Hr): Fast Med Slow
Heat Pump (Heat)................................ 0.9°F 1.2°F 1.7°F
Heat Pump (Cool) ................................ 0.9°F 1.2°F 1.7°F
Auxiliary Heat ...................................... 0.5°F 0.75°F 1.9°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing maximum
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4” H x 6” W x 1-1/8” D
SPECIFICATIONS
N
O
DE PIÈCE 37-7511003
Remplace 37-7511002
2042
1F83H-21PR (programmable)
Instructions d’installation et d’utilisation
Thermostat avec thermopompe
Alimentation par piles ou câblée avec l commun
Applications du thermostat
Nombre
maximum
d’étages
chauage/
climatisation
Systèmes thermopompe à compresseur
mono-étage (source d’air ou géothermique) –
1 étage chauage auxiliaire/d’urgence,
electrique ou au gaz (bi-carburant)
2/1
Installation du thermostat
2-4
Câblage
2
Menu de l’installateur
3-4
Utilisation du thermostat
5-7
Aperçu du thermostat
5
Menu de l’utilisateur
6
Fonctionnement du thermostat
6
Horaire du thermostat
7
Dépannage
7-8
Ligne d’assistance pour les propriétaires
8
INDEX
AVIS RELATIF AU MERCURE : Ce produit ne contient pas de
mercure. Il peut toutefois remplacer un produit qui en contient.
Le mercure et les produits contenant du mercure ne doivent pas
être jetés dans les ordures ménagères. Consultez le site
www.thermostat-recycle.org pour connaître les endroits où
vous pouvez envoyer le produit contenant du mercure.
Paramètres électriques :
Batterie ................................................... 20 à 30 V c.a., NEC classe II, 50/60 Hz
Câblé ...................................................... 20 à 30 V c.a., NEC classe II, 50/60 Hz
Charge à la borne ......................................... 1,5 A par borne, 2,5 A maximum pour toutes les bornes combinées
Plage de réglage .......................................... 45 à 99 °F (7 à 37 °C)
Diérentiels nominaux (@ 6 °F/h) : Rapide Moyen Lent
Thermopompe (chauage) ..................... 0,9 °F 1,2 °F 1,7 °F
Thermopompe (climatisation) ................. 0,9 °F 1,2 °F 1,7 °F
Chauage auxiliaire ................................ 0,5 °F 0,75 °F 1,9 °F
Température ambiante de fonctionnement . 32 °F à +105 °F (0 à +41 °C)
Plage de températures achées .................... 32 °F à +99 °F (0 à 37 °C)
Humidité de fonctionnement ....................... 90 % max. sans condensation
Plage de températures d’expédition ............. -20 °F à + 150 °F (-29 à +65 °C)
Dimensions du thermostat ........................... 3-3/4 po H x 6 po L x 1-1/8 po P
SPÉCIFICATIONS
Accessoire en opon : plaque murale F61-2663, 6 3/4 po L x 4 1/2 po H
Optional Accessory: Wall
Cover-Up Plate F61-2663,
6 3/4” W x 4 1/2” H
Programming
made Simple
See page 7
emerson.com/white-rodgers
emerson.com/white-rodgers

Questions and Answers

  • R
    Robert RichardsonJul 27, 2025
    What to do if my Emerson 1F83H-21PR Thermostat is not blowing heat?
    • M
      Melinda CampbellJul 28, 2025
      If your Emerson Thermostat isn't producing heat, consider the following: * System Switch not set to Heat: Set the System Switch to Heat and raise the setpoint above room temperature. * Loose connection to thermostat or system: Verify thermostat and system wires are securely attached.
  • M
    mooreshannonAug 1, 2025
    What to do if my Emerson 1F83H-21PR has no heat, no cool, or no fan?
    • L
      Lindsay WardAug 1, 2025
      If your Emerson Thermostat isn't producing heat, cool air, or running the fan, there are several potential causes: * A blown fuse or tripped circuit breaker: Replace the fuse or reset the breaker. * Furnace power switch is OFF: Turn the switch to ON. * Furnace blower compartment door panel is loose: Replace the door panel correctly to engage the safety interlock or door switch. * Loose connection to the thermostat or system: Tighten the connections.
  • S
    Seth BurtonAug 5, 2025
    Why does my Emerson 1F83H-21PR Thermostat say 'Call for Service'?
    • D
      David TuckerAug 5, 2025
      The “Call for Service” icon on your Emerson Thermostat indicates a few potential issues: * The heating system can't heat the space to within 10 degrees of the setpoint within 2 hours: Refer to troubleshooting steps for a 'No Heat' condition. * The cooling system can't cool the space to within 10 degrees of the setpoint within 2 hours: Refer to troubleshooting steps for a 'No Cool' condition. * If “--” is displayed for the Room Temperature, a replacement thermostat is needed: Replace the thermostat. * None of the buttons operate on the thermostat: Make sure keypad lockout is not turned on (denoted by icon).
  • W
    wayne48Aug 9, 2025
    What to do if my Emerson 1F83H-21PR Thermostat is not blowing cool air?
    • D
      Dean RasmussenAug 9, 2025
      If your Emerson Thermostat isn't blowing cool air, check these: * System Switch not set to Cool: Set the System Switch to Cool and lower the setpoint below room temperature. * Loose connection to thermostat or system: Verify thermostat and system wires are securely attached.
  • K
    Kyle JohnsonAug 13, 2025
    Why is the heat, cool, or fan running constantly on my Emerson Thermostat?
    • C
      clayton76Aug 13, 2025
      If the heat, cool, or fan runs constantly on your Emerson Thermostat, there might be a short in the wiring, thermostat, or system. Check each wire connection to ensure they are not shorted or touching other wires.
  • J
    John OrozcoAug 17, 2025
    Why does my Emerson 1F83H-21PR Thermostat Display & Thermometer Disagree?
    • S
      Stacey JohnsonAug 17, 2025
      If your Emerson Thermostat display and thermometer disagree, the thermostat display requires adjustment. The display can be adjusted +/-5°.
  • M
    mariebrewerAug 22, 2025
    Why does my Emerson Furnace (Air Conditioner) Cycles Too Fast or Slow?
    • K
      kristin88Aug 22, 2025
      The cycle rate of your Emerson Furnace (Air Conditioner) might be influenced by the location of the thermostat and/or the size of the Heating System. To increase cycle time, choose SLO for slow cycle in the Installer menu.

Summary

SPECIFICATIONS

Thermostat Applications

Describes compatible HVAC systems for the thermostat.

Electrical and Operational Specifications

Details electrical ratings, operational ranges, and dimensions.

Mercury Disposal Information

Advises on proper disposal of mercury-containing products.

THERMOSTAT INSTALLATION

WIRING

Details terminal designations and wiring for typical systems.

Installation Precautions and Warnings

Lists safety guidelines and electrical hazards during installation.

INSTALLER MENU

Jumper Wire and Terminal Switch Configuration

Explains W2/E jumper and O/B terminal switch settings.

Installer Menu Settings Overview

Lists configurable installer menu options and their default settings.

TEST EQUIPMENT AND SYSTEM OPERATION

System Operation Testing

Guides for testing fan, heating, auxiliary, and cooling system functions.

Installation Caution

Warns against operating cooling below 50°F and about compressor oil.

USING THE THERMOSTAT

Thermostat Overview

Explains the features, display, and location of buttons and switches.

Display Indicators

Describes the meaning of various icons and messages on the thermostat display.

USER MENU AND THERMOSTAT OPERATION

User Menu Customization

Details how to customize schedule type, early start, display light, and filter reminders.

Basic Operation Functions

Explains setting time/day, holding temperature, and program override.

THERMOSTAT SCHEDULE; PROGRAMMING

Energy Saving Factory Schedule

Presents the default programmed heating and cooling temperature schedules.

Modifying Heating and Cooling Schedules

Provides step-by-step instructions to change programmed schedules.

TROUBLESHOOTING

Common Symptoms and Corrective Actions

Addresses issues like no heat/cool/fan and provides solutions.

Advanced Troubleshooting

Covers constant running, display discrepancies, and cycle rate issues.

Resetting Thermostat Settings

Instructions for resetting the thermostat to factory defaults.

Emerson 1F83H-21PR Specifications

General IconGeneral
DisplayBacklit LCD
ProgrammableYes
Wi-Fi CapabilityNo
Voltage24 VAC
CompatibilityHeating and Cooling Systems
Power SourceBattery
Product TypeThermostat
Battery2 AA batteries
TypeDigital Programmable Thermostat