Model 8800C and Model 8800A
Smart Vortex Flowmeter
00809-0100-4003
English
Rev. JA

Table of Contents

Questions and Answers

  • J
    Jeffrey SnyderAug 15, 2025
    How to solve communication problems with HART-based Communicator Emerson Measuring Instruments?
    • S
      Sarah RodriguezAug 15, 2025
      To troubleshoot communication issues with your HART-based Communicator, start by checking for a minimum of 12 V dc at the transmitter terminals. Then, check the communications loop. Ensure there's a loop resistor (250 to 1000 ohms) in place. Verify the transmitter is not in multidrop or burst mode. If you have a three-wire pulse installation, remove the pulse connection. If these steps don't resolve the issue, consider replacing the electronics.
  • E
    evan57Aug 18, 2025
    What to do if there is flow in pipe but no output from Emerson Measuring Instruments?
    • B
      Bianca KingAug 18, 2025
      First, ensure the meter is installed correctly, with the arrow indicating the direction of process flow. Next, perform basic checks for an incorrect 4–20 mA output. After that, check and correct configuration parameters in the following order: K-factor, service type, materials, units, process temperature, damping value, 4–20 mA trim, meter body number, density, pulse mode, pulse scaling, line size, pipe diameter, LRV, URV, LP corner, trigger level, and low flow cutoff. Also, verify that the flow is within measurable flow limits. Finally, refer to Appendix E: Electronics Verification for the electronics verification procedure.
  • M
    Michael LivingstonAug 22, 2025
    What to do if Emerson Measuring Instruments shows incorrect 4–20 mA Output?
    • B
      brycewilliamsAug 22, 2025
      If you're seeing an incorrect 4–20 mA output, first check for 12 V dc at the transmitter terminal. Then, check the URV, LRV, Density, Special Units, and LFC, and compare these inputs with the sizing program results, correcting the configuration as needed. Finally, perform a 4–20 mA loop test.
  • C
    Casey AdamsAug 25, 2025
    Why is Emerson 8800A Measuring Instruments giving a 50/60 Hz measurement?
    • R
      robinsonkimberlyAug 26, 2025
      A 50/60 Hz measurement may indicate electrical or magnetic interference. Ensure the electronics mounting screws (3) are securely installed. Check the meter ground and measure voltage levels between the 4–20 mA and pulse outputs and the electronics housing, ensuring the common mode voltage is less than 30 Vrms. If the meter is near a large motor or electric furnace, try different orientations to reduce noise, ensuring magnetic fields are less than 5 gauss. For remote mount installations, try an integral mount to see if the problem is corrected, and measure AC voltage from the electronics housing to the SMA connector, ensuring the voltage is less than 1Vrms.
  • D
    Derek HoffmanAug 29, 2025
    What to do for Emerson Measuring Instruments output with no actual flow?
    • B
      Brandi ScottAug 29, 2025
      First, perform basic checks for an Incorrect 4–20 mA Output. Then, check and correct configuration parameters in this order: K-factor, service type, materials, units, process temperature, damping value, 4–20 mA trim, meter body number, density, pulse mode, pulse scaling, line size, pipe diameter, LRV, URV, LP corner, trigger level, low flow cutoff. After that, check sizing to ensure flow is within measurable flow limits. Finally, using a HART-based communicator, read the shedding frequency.
  • E
    efarrellSep 1, 2025
    How to troubleshoot application problems with Emerson 8800A?
    • R
      Rhonda BrownSep 1, 2025
      To address application problems, start by calculating the expected frequency. If the actual frequency is the same, check the configuration. Then, verify that the application meets the viscosity and specific gravity requirements for the line size. Finally, recalculate the back pressure requirement and, if necessary and possible, increase back pressure, flow rate, or operating pressure.
  • L
    Lori CortezSep 4, 2025
    Why is Emerson 8800A Measuring Instruments having a vibration problem?
    • E
      Erica BurgessSep 4, 2025
      To address vibration issues, try adjusting the signal processing parameters. If that doesn't work, rotate the meter 90 degrees. As a final measure, add support to the line near the meter to dampen the vibration.
  • S
    Scott JohnsonSep 8, 2025
    What to do if Emerson 8800A Measuring Instruments has incorrect pulse output?
    • A
      Alison HayesSep 8, 2025
      First, check that the 4–20 mA output is correct. Then, check the pulse counter specifications. Next, check the pulse mode and scaling factor, ensuring the scaling factor is not inverted. Also, check for corrosion on the terminal block. If necessary, replace the electronics. Finally, see Appendix E: Electronics Verification for the electronics verification procedure.
  • V
    Veronica NelsonSep 12, 2025
    How to troubleshoot electronics issues in Emerson 8800A Measuring Instruments?
    • B
      Benjamin HodgeSep 12, 2025
      To troubleshoot electronics, run a self-test using the Model 268/HART Communicator. You can also insert a test signal using a sensor simulator. Check the configuration, LFC, trigger level, and the relationship between standard and actual flow. If problems persist, consider replacing the electronics.

Summary

Model 8800 C and Model 8800 A Smart Vortex Flowmeter

Section 2 Installation

Commissioning

Outlines the process for configuring and verifying the flowmeter before operational use.

Hazardous Locations

Describes suitability and certifications for operation in potentially explosive atmospheres.

Installation Tasks

Covers essential mechanical and electrical steps for installing the flowmeter.

Wafer-Style Flowmeter Alignment and Mounting

Details the procedure for centering and mounting the wafer-style meter body.

Wiring Procedure

Describes how to connect the signal terminals and power supply for the flowmeter.

Software Configuration

Guides on configuring software to meet application requirements.

Section 3 Operation

Diagnostics;Service

Details functions for verifying operation and troubleshooting suspected component failures.

Section 4 Hardware and Software Maintenance and Troubleshooting

Safety Messages

Emphasizes critical safety precautions for personnel performing maintenance and troubleshooting.

Troubleshooting Tables

Provides a guide to common problems, their causes, and corrective actions.

Advanced Troubleshooting

Explains advanced features for diagnosing and troubleshooting electronic issues.

Appendix E Electronics Verification

Safety Messages

Highlights safety precautions for performing electronics verification procedures.

Electronics Verification Using Flow Simulation Mode

Explains how to verify electronics using internal fixed or varying flow simulation.

Electronics Verification Using an External Frequency Generator

Describes how to verify electronics using an external signal source.

Emerson 8800A Specifications

General IconGeneral
Model8800A
CategoryMeasuring Instruments
ManufacturerEmerson
TypeVortex Flow Meter
Line Size1/2 to 12 inches
Output4-20 mA
MaterialStainless Steel
Power Supply24 VDC nominal (12-42.4 VDC)