Optional: Foot Pre-Check
To check foot condition, press [F12] before
sweeping laser fixtures and follow on-screen
instructions. Use a feeler gauge to determine
required shim correction. The Soft Foot option
provides you with a sense of severity without
showing numbers. The FDI option will provide an
estimate of the required shim.
Bluetooth Set- Up
1. Press [Home] > [F5] Comm Setup >
[F7] Bluetooth Setup.
2. Press [F2] Bluetooth to enable or disable the
Bluetooth radio. When the radio is enabled,
the Bluetooth LED on the top of the analyzer
turns on and the icon appears in the upper corner
of the screen.
3. Press [F7] Pair to pair the sensor.
“Paired” appears next to the device
once the laser heads are connected
to the analyzer. To differentiate
between laser heads and
headphones, a laser image as shown to the right
is displayed next to the serial number.
1 Enter Dimensions 2 Sweep Laser Heads 3 Move Machine
Values for A, B, E and
RPM are required.
Use [<] and [>] to
move between elds.
Optional machines
types enable entry of
values for C and D for
the other machine.
Note: Use [./] to
calculate fractions.
Example: 30 3/8 = [3]
[0] [./] [3] [./] [./] [8]
Press [ENTER]
to initialize
laser xtures.
The Vertical
Machine Move
indicates how much
to shim/drop each
machine foot.
Sweep laser heads.
Start anywhere.
Stop anywhere.
Minimum
recommended
sweep size is 45°.
Press [ENTER]
to retrieve data
via Bluetooth.
When viewing the
Horizontal Move
screen, press [F12]
for ‘LIVE MOVE’.
Place laser xtures
in desired position
and press [ENTER]
to start.
OK = Good
X = Soft
Display Meaning
Way out.
More than 2x tolerance.
Getting close.
1-2x tolerance.
Good job!
Below acceptable tolerance.
Great job!
Below excellent tolerance.
Shaft Alignment Indicator
The bull’s eye display continuously updates
alignment status.
Emerson
Reliability Solutions
835 Innovation Drive
Knoxville, TN 37932 USA
+1 865 675 2400
www.emerson.com/ams
XX = Bad
XXX = Extreme