A.2 Physical specifications
Battery
Table A-1: Tadiran Lithium Batteries Model TL-4920/VE
Nominal capacity @ 3 mA, to 2 V 8.5 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 75 mA
Maximum 1 sec. pulse capability 200 mA
Weight 49.5 g (1.746 oz)
Volume 26 cc
Operating temperature range -55 ºC to +85 ºC
U.L. Component Recognition, MH 12193
Field Communicator connections
HART ports
Clips attached to the HART ports
Mounting
Mounting tools and supplies depend on the mounting mechanism. For more information,
see Mounting tools and supplies.
Mounting screw thread is 1/4 - 28
Weight
0.697 lb (315 g)
Enclosure ratings
Housing is NEMA 4X and IP66
A.3 Performance specifications
Temperature Limits
The device is rated for operation in the range from -40 to +85C.
Table A-2: Temperature limits
Device Operating limit Storage limit
AMS Wireless Vibration
Monitor
-40 to +85C
-55 to +85C
Note
Prolonged storage above +75 C
degrades battery life
Specifications and reference data User Guide
August 2020 MHM-97927-PBF
66 MHM-97927-PBF, Rev 1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson AMS Wireless Vibration Monitor and is the answer not in the manual?

Emerson AMS Wireless Vibration Monitor Specifications

General IconGeneral
BrandEmerson
ModelAMS Wireless Vibration Monitor
CategoryMonitor
LanguageEnglish

Related product manuals