EasyManua.ls Logo

Emerson CBA730 - Section 5: Field Conversions; High Temperature Service (-10 TRIM); Low Temperature Service (-11 TRIM); Add an Extended Stop (ES) to Housing Adapter (6-10)

Emerson CBA730
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Instructions
137462E Rev. D
August 2015
21
Section 5: Field Conversions
Field Conversions
Section 5: Field Conversions
5�1 High Temperature Service (-10 TRIM)
5.1.1 Disassemble and reassemble actuator per Sections 1 through Section 4 using
new -10 (high temperature) Service Kit.
5�2 Low Temperature Service (-11 TRIM)
5.2.1 Disassemble and reassemble actuator per Sections 1 through Section 4 using
new -11 (low temperature) Service Kit.
5�3 Add an Extended Stop (ES) to Housing Adapter (6-10)
NOTE:
Prior to disassembly, review all of Section 1 Introduction and Section 2 - Actuator
Disassembly, step 2.1 - General Disassembly.
5.3.1 Stop screw (6-30) removal from housing adapter (6-10).
5.3.1.1 Loosen and remove hex nut (6-40) and washer (6-90) from stop screw
(6-30) located in housing adapter (6-10).
5.3.1.2 Remove stop screw (6-30) from housing adapter (6-10).
NOTE:
Prior to reassembly, review all of Section 3 - Actuator Reassembly, step 3.1 - General
Reassembly.
5.3.2 ES (6-30) installation into housing adapter (6-10).
5.3.2.1 Lubricate ES (6-30) and install into housing adapter (6-10).
5.3.2.2 Install O-ring seal (7-30) onto ES (6-30).
NOTE:
Move the O-ring seal (7-30) down the ES until it is next to housing
adapter (6-10).
5.3.2.3 Install washer (4-90) onto ES or stop screw (4-30).
NOTE:
Push the washer down the ES or stop screw until it is next to the housing
adapter (6-10).

Related product manuals