Service Instructions
137462E Rev. D
August 2015
3
Section 1: Introduction
Introduction
WARNING: FOLLOW COMPANY SAFETY PROCEDURES
This procedure should not supersede or replace any customer’s plant safety or work
procedures. If a conict arises between this procedure and the customer’s procedures, the
differences should be resolved in writing between an authorized customer's representative
and an authorized Bettis representative.
1�4 Bettis Reference Materials
1.4.1 CBA-300 assembly drawing use part number 129742.
1.4.2 CBA-300-M3HW assembly drawing use part number 129744.
1�5 Service Support Items
1.5.1 Bettis Service Kit.
1.5.2 Commercial leak testing solution.
1.5.3 Non-hardening thread sealant.
1�6 Lubrication Requirements
1.6.1 The actuator should be relubricated at the beginning of each service interval using
the following recommended lubricants.
NOTE:
Lubricants other than those listed in steps 1.6.2 should not be used without prior written
approval of Bettis Product Engineering.
1.6.2 All temperature services (-50°F to +350°F)/(-45.5°C to 176.6°C) use Bettis ESL-5
lubricant. ESL-5 lubricant is contained in the Bettis module service kit in tubes and
the tubes are marked ESL-4, 5 and 10 lubricant.
1�7 General Tool Information
1.7.1 All threads on CBA series actuators are Inch Unied and NPT.
1.7.2 All tools/Hexagons are American Standard inch.
1.7.3 Suggested tools: Two adjustable wrenches, small standard screwdriver with sharp
edges rounded off, medium size standard screwdriver, external snap ring pliers, drive
ratchet / deep well socket set and torque wrench (up to 3,000 inch pounds / 339 N-m).