EasyManua.ls Logo

Emerson Control Techniques EN-204 - Input;Output and Drive Enable Wiring

Emerson Control Techniques EN-204
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101
Installation
Figure 71: Epsilon Brake Wiring Diagram using the Command Connector
Figure 72: Epsilon Brake Wiring Diagram using the I/O Connector
Input/Output and Drive Enable Wiring
Drives are equipped with five optically isolated input lines (one is dedicated to a drive enable
function) and three optically isolated output lines. They are designed to operate from a +10
to 30 VDC source. All inputs and outputs are configured as sourcing. You are responsible for
choosing a load that will limit each output’s current to less than 150 mA.
Bottom View
-
+
K1
A
Internal
to Motor
C
B
Red +
Black -
Connected to
grounded
mounting panel.
Single point
PE ground.
11
A2
14
A1
2 Amp
Fuse
Customer
supplied drive
enable contact
Relay:
EMC #BRM-1
24 VDC
Motor
Output #3
Drive Enable
I/O Common
I/O Common
I/O Supply
34
33
32
31
16
17
I/O Supply
J5
1 Amp
Fuse
CBMS-xxx Cable
Front View
19
10
8
Output #3
Drive Enable
I/O Common
I/O Supply
J3
-
+
K1
A
Internal
to Motor
C
B
Red +
Black -
Connected to
grounded
mountin
g
panel.
Single point
PE ground.
11
A2
14
A1
2 Amp
Fuse
Customer
supplied drive
enable contact
Relay:
EMC #BRM-1
24 VDC
Motor
1 Amp
Fuse
CBMS-xxx Cable