Installation Guidelines
Compressor Handling
Delivery
Please check whether the delivery is correct and complete. Any deciency should be reported immediately in writing.
Transport and Storage
WARNING
High pressure! Injury to skin and eyes, possible! Be careful when opening connections on a pressurized item.
WARNING
Risk of collapse! Personal injuries! Move compressors only with appropriate mechanical or handling equipment according to
weight. Keep in the upright position. Stack and transit as shown below. Keep the packaging dry at all times.
• Suction and discharge shut-off valves
• Oil charge, oil sight glass
• Mounting kit
• CoreSense™ Diagnostics module
• Holding charge up to 2.5 bar(g) (dry air)
Compressors are delivered on pallets. Cooling fans are delivered in separate cartons. Accessories may be mounted or delivered loose.
Solenoid valves are never mounted.
Figure 4
IMPORTANT
Handling damage! Compressor malfunction! Only use the lifting eyes whenever the compressor requires positioning. Using
discharge or suction connections for lifting may cause damage or leaks.
Positioning and Securing
If possible, the compressor should be kept vertical during handling. For safety reasons, two lifting eyes should be tted before moving a
compressor (½” - 13 UNC). Otherwise refer to drawings on Figure 5 to see how to apply other lifting methods.
In order to avoid refrigerant leaks or other damage the compressors should not be lifted by the service valves or other accessories.
4M*
max. 220 kg
6M*
max. 260 kg
Figure 5