8
Performance Table
Q=Capacity (kW) P=Power input (kW) 3-Phase
R22 50 Hz
Compressor
Condensing
Temperature
o
C
Evaporating Temperature (
o
C)
-12 -10 -5 0 5 10 12.5
ZBD48KQ
Q
15
11.55 12.20 14.05 16.30
20 12.10 12.85 15.05 17.60 20.60
30 11.80 12.75 15.25 18.15 21.40 25.20 27.30
40 10.65 11.60 14.10 17.00 20.30 24.00 26.00
50 9.79 10.60 12.85 15.35 18.25 21.60 23.40
55 - 10.55 12.45 14.70 17.30 20.30 22.00
60 - - 12.50 14.35 16.60 19.15 20.60
65 - - - 14.45 16.20 18.30 19.50
P
15 2.96 3.11 3.51 3.97
20 2.92 3.01 3.28 3.58 3.93 - -
30 3.35 3.39 3.49 3.59 3.71 3.86 3.96
40 4.11 4.16 4.24 4.29 4.33 4.37 4.40
50 4.76 4.87 5.10 5.25 5.37 5.45 5.48
55 5.07 5.43 5.70 5.90 6.06 6.13
60 5.62 6.04 6.38 6.65 6.77
65
6.23 6.74
7.17 7.35
Notes: Suction Return Temperature 18.3
o
C
Suction Superheat 11.0K
Liquid subcooling 0.0K