Document Part # 026-4909 Rev 0 11-NOV-2010 Page 4 of 12
©2010 Emerson Climate Technologies Retail Solutions, Inc. This document may be photocopied for personal use.
Visit our website at http://www.emersonretailsolutions.com/ for the latest technical documentation and updates.
Installation Instructions: XJ Scroll Condenser to E2
technical bulletin
Dip Switch Address Settings
•No.1~6: Set Slave Address
•No.7: Set Baud Rate
•No.8: Set Parity
12345678
Set Address Address
OFF OFF OFF OFF OFF ON - - Address=1
OFF OFF OFF OFF ON OFF - - Address=2
OFF OFF OFF OFF ON ON - - Address=3
OFF OFF OFF ON OFF OFF - - Address=4
OFF OFF OFF ON OFF ON - - Address=5
OFF OFF OFF ON ON OFF - - Address=6
OFF OFF OFF ON ON ON - - Address=7
OFF OFF ON OFF OFF OFF - - Address=8
OFF OFF ON OFF OFF ON - - Address=9
OFF OFF ON OFF ON OFF - - Address=10
OFF OFF ON OFF ON ON - - Address=11
OFF OFF ON ON OFF OFF - - Address=12
OFF OFF ON ON OFF ON - - Address=13
OFF OFF ON ON ON OFF - - Address=14
OFF OFF ON ON ON ON - - Address=15
OFF ON OFF OFF OFF OFF - - Address=16
OFF ON OFF OFF OFF ON - - Address=17
ON ON OFF OFF OFF ON - - Address=18
OFF ON OFF OFF ON ON - - Address=19
OFF ON OFF ON OFF OFF - - Address=20
OFF ON OFF ON OFF ON - - Address=21
OFF ON OFF ON ON OFF - - Address=22
OFF ON OFF ON ON ON - - Address=23
OFF ON ON OFF OFF OFF - - Address=24
OFF ON ON OFF OFF ON - - Address=25
OFF ON ON OFF ON OFF - - Address=26
Table 2 - Address Settings