1592027610 XW60LT-XW60LRT GB r1.0 13.02.2012.doc XW60LT – XW60LRT 6/6
Label
Name Range °C/°F Level
AH2
Differ. for condenser temp. alar. recovery
[0.1°C to 25.5°C]
[1°F to 45°F]
5 Pr2
Ad2
Condenser temperature alarm delay 0 to 254 min; 255=nU 15 Pr2
dA2
Delay of cond. temper. alarm at start up 0.0 to 23h50min 1,3 Pr2
bLL
Compr. off for condenser low
temperature alarm
n(0); Y(1) n Pr2
AC2
Compr. off for condenser high
temperature alarm
n(0); Y(1) n Pr2
tbA Alarm relay disabling n(0); Y(1) y Pr2
oA3
Third relay configuration
ALr = alarm; dEF = do not select
it; Lig =Light; AUS =AUX;
onF=always on; Fan= do not
select it; db = neutral zone; cP2
= second compressor; dF2 = do
not select it; HES = night blind
Lig Pr2
AoP
Alarm relay polarity (oA3=ALr) oP; cL cL Pr2
i1P Digital input polarity oP=opening; CL=closing cL Pr1
i1F Digital input 1 configuration
EAL, bAL, PAL, dor; dEF; Htr,
AUS
dor Pr1
did Digital input alarm delay 0 to 255 min 15 Pr1
i2P Digital input polarity oP=opening; CL=closing cL Pr2
i2F Digital input configuration
EAL, bAL, PAL, dor; dEF; Htr,
AUS
EAL Pr2
d2d Digital input alarm delay 0 to 255 min 5 Pr2
nPS
Number of activation of pressure switch 0 to 15 15 Pr2
odc
Compress and fan status when open
door
no; Fan; CPr; F_C F-c Pr2
rrd Regulation restart with door open alarm n(0); Y(1) y Pr2
HES
Differential for Energy Saving
[-30 to 30°C]
[-54 to 54°F]
0 Pr2
Hur*
Current hour 0 to 23 - rtc
Min*
Current minute 0 to 59 - rtc
dAY*
Current day Sun to SAt - rtc
Hd1*
First weekly holiday Sun to SAt; nu nu rtc
Hd2*
Second weekly holiday Sun to SAt; nu nu rtc
ILE*
Energy Saving cycle start during
workdays
0.0 to 23h50min 0 rtc
dLE*
Energy Saving cycle length during
workdays
0.0 to 24h00min 0 rtc
ISE*
Energy Saving cycle start on holidays 0.0 to 23h50min 0 rtc
dSE*
Energy Saving cycle length on holidays 0.0 to 24h00min 0 rtc
Ld1*
1
st
workdays defrost start 0.0 to 23h50min; nu 6.0 rtc
Ld2*
2
nd
workdays defrost start 0.0 to 23h50min; nu 13.0 rtc
Ld3*
3
rd
workdays defrost start 0.0 to 23h50min; nu 21.0 rtc
Ld4*
4
th
workdays defrost start 0.0 to 23h50min; nu 0.0 rtc
Ld5*
5
th
workdays defrost start 0.0 to 23h50min; nu 0.0 rtc
Ld6*
6
th
workdays defrost start 0.0 to 23h50min; nu 0.0 rtc
Sd1*
1
st
holiday defrost start 0.0 to 23h50min; nu 6.0 rtc
Sd2*
2
nd
holiday defrost start 0.0 to 23h50min; nu 13.0 rtc
Sd3*
3
rd
holiday defrost start 0.0 to 23h50min; nu 21.0 rtc
Sd4*
4
th
holiday defrost start 0.0 to 23h50min; nu 0.0 rtc
Sd5*
5
th
holiday defrost start 0.0 to 23h50min; nu 0.0 rtc
Sd6*
6
th
holiday defrost start 0.0 to 23h50min; nu 0.0 rtc
LoC
Keyboard lock timer nu; 10 to 255 sec 60 Pr2
Adr Serial address 1 to 247 1 Pr2
PbC
Kind of probe PtC; ntC ntc Pr2
onF
on/off key enabling nu, oFF; ES oFF Pr2
dP1
Room probe display Read Only - Pr2
dP2
Evaporator probe display Read Only - Pr2
dP3
Third probe display Read Only - Pr2
dP4
Fourth probe display Read Only - Pr2
rSE Real set actual set - Pr2
rEL Software release Read Only 6.9 Pr2
Ptb Map code Read Only Pr2
* Only for model with real time clock