EasyManua.ls Logo

Emerson Fisher 2052 - Educational Services; Installation

Emerson Fisher 2052
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual
D103296X012
2052 Actuator
June 2017
4
Educational Services
For information on available courses for Fisher 2052 actuators, as well as a variety of other products, contact:
Emerson Automation Solutions
Educational Services - Registration
Phone: 1-641-754-3771 or 1-800-338-8158
E-mail: education@emerson.com
emerson.com/fishervalvetraining
Specifications
Specifications are shown in table 1 for 2052 actuators. Specifications for actuator operation are stamped on a metal
nameplate attached to the actuator.
Table 6. Bolting Torque Requirements
(1)
DESCRIPTION KEY NUMBER
ACTUATOR
SIZE
TORQUE
FASTENER LUBRICATION
NSm LbfSft
Rod End Bearing Clamping Bolt
Torque , Key 16
1
2
3
38
180
400
28
130
295
None
End Plate to Housing Bolt
Torque, Key 4
1
2
3
68
120
210
50
90
155
None
Diaphragm Plate to Rod Bolt
Torque, Key 7
1
2
3
27
115
300
20
85
220
Anti-Seize Lubricant
Casing Bolt Torque, Key 8
1
2
3
55
55
55
40
40
40
None
Housing to Yoke Bolt Torque,
Key 28
1
2
3
27
68
245
20
50
180
None
Lever‐Spline Clamping Bolt
Torque, Key 15
1
2
3
38
115
175
28
85
130
None
Optional Lockout Kit Mounting
Bolt Torque, Key 53
1
2
3
NA
88
340
NA
65
250
None
1. Exceeding any torque requirements could damage the actuator and impair safe operation.
Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations.
Check with your process or safety engineer for any other hazards that may be present from exposure to process media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
CAUTION
To avoid parts damage, do not apply pressure that exceeds the Maximum Diaphragm Casing Pressure in table 1.
Use pressure‐limiting or pressure‐relieving devices to prevent the Operating Pressure from exceeding the values shown in
table 3.