Emerson Fisher FIELDVUE DVC6215 - ATEX Certifications

Emerson Fisher FIELDVUE DVC6215
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Start Guide
D103556X012
DVC6200 Digital Valve Controllers
August 2015
58
ATEX
Flameproof II 2 G
WARNING
Do not open while energized.
Potential electrostatic charging hazard. See warning on page 3.
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION FIELDBUS, PROFIBUS)
Ex d IIC T5 (Ta ≤ 85°C)
Ex d IIC T6 (Ta ≤ 80°C)
Operating ambient temperature
 Standard construction -40_C to +85_C,
 Extreme temperature construction -52_C to +85_C
Type n II 3 G
WARNING
Do not open while energized.
Potential electrostatic charging hazard. See warning on page 3.
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION FIELDBUS, PROFIBUS)
Ex nC IIC T5 (Ta ≤ 80°C)
Ex nC IIC T6 (Ta ≤ 75°C)
Operating ambient temperature
Standard construction -40_C to +80_C,
Extreme temperature construction -52_C to +80_C
Intrinsically Safe
WARNING
Potential electrostatic charging hazard. See warning on page 3.
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION FIELDBUS, PROFIBUS)
II 1 GD
Operating ambient temperature
Standard construction -40_C to +80_C,
Extreme temperature construction -52_C to +80_C
DVC6215
II 1 G
- 52_C Ta + 125_C