8-3
A8AN5SCP1
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Power Supply 1/3 Schematic Diagram
CN301
13.4
20
33.3
43.4
50
6 24.9
7 13.3
8-7.0
90
10 3.4
11 0
12 3.4
13 0
14 3.4
15 3.4
16 3.5
17 0
18 3.5
19 3.5
20 5.2
21 0
22 3.3
23 3.2
VOLTAGE CHART
Pin No. Voltage
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
4A/125V