1.5 Environmental limits
Environmental specificationsTable 1-5:
Type Value
Ambient temperature limits
(Operating)
–40 to +131 °F (–40 to +55 °C)
Ambient temperature limits
(Storage)
–40 to +185 °F (–40 to +85 °C)
Humidity limits 5 to 95% relative humidity, non-condensing at 140 °F (60 °C)
Vibration limits Meets IEC 60068-2-6, endurance sweep, 5 to 2000 Hz, 50 sweep
cycles at 1.0 g
EMI effects Complies with EMC Directive 2004/108/EC per EN 61326 Indus-
trial
Complies with NAMUR NE-21 (22.08.2007)
Ambient temperature effect
(analog output option)
On mA output: ±0.005% of span per °C
1.6 Hazardous area classifications
If you plan to mount the transmitter in a hazardous area:
Verify that the transmitter has the appropriate hazardous area approval. Each
transmitter has a hazardous area approval tag attached to the transmitter housing.
Ensure that any cable used between the transmitter and the sensor meets the
hazardous area requirements.
1.7 Power requirements
The transmitter must be connected to a DC voltage source.
Minimum 19.2 to 28.8 VDC
6.3 watts
Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements
Planning
Installation Manual 5