Quick Start Guide
7
September 2017
Figure 9. Rosemount 1195 Flowmeter Orientation with Flange by Flange
Manifold
Note
For saturated steam that is not high quality, it is recommended to mount in a vertical line
to avoid damming effect of the liquid.
Gas (horizontal) Gas (vertical)
Liquid (horizontal) Liquid (vertical)
Steam (horizontal) Steam (vertical)
A. 120° recommended zone
B. Horizontal plane
C. Vertical plane
D. 360° recommended zone
E. Block valves
F. Vent valves
A
B
C
00825-0100-4686 FA.fm Page 7 Thursday, September 21, 2017 10:45 AM