EasyManua.ls Logo

Emerson Rosemount 2120 - User Manual

Emerson Rosemount 2120
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Quick Start Guide
00825-0100-4030, Rev GA
June 2020
Rosemount
2120 Level Switch
Vibrating Fork

Other manuals for Emerson Rosemount 2120

Questions and Answers

  • B
    burnsmichelleAug 12, 2025
    What to do if my Emerson Switch does not switch?
    • T
      taraberryAug 12, 2025
      If your Emerson Switch isn't switching, start by checking the power supply. Also, verify the load on the direct load switching electronics model.
  • S
    Stacy GibbsAug 16, 2025
    Why is my Emerson Rosemount 2120 Switch switching faulty?
    • M
      Michael PatelAug 16, 2025
      If the Emerson Switch exhibits faulty switching due to turbulence, try setting a longer switching time delay. If excessive electrical noise is the cause, suppress the source of the interference. If the cassette has been fitted from another Rosemount 2120, fit the factory supplied cassette and then calibrate.
  • J
    justin42Aug 19, 2025
    Why is there a five second delay on my Emerson Rosemount 2120 Switch?
    • B
      Brooke LaraAug 19, 2025
      This five-second delay after changing the mode or delay on your Emerson Switch is normal and occurs whenever you make changes to the settings.
  • C
    chaneyallenAug 23, 2025
    What to do if the LED is flashing once every four seconds on Emerson Rosemount 2120?
    • R
      Ryan KirbyAug 23, 2025
      If the LED on your Emerson Switch is flashing once every four seconds, examine the electrical installation for a load fault, meaning the current is too high or there's a short-circuit.
  • M
    myersjamesAug 27, 2025
    How to fix incorrect switching on Emerson Rosemount 2120?
    • A
      Ashley DavisAug 27, 2025
      If you notice incorrect switching with your Emerson Switch, check the wiring connections.
  • J
    Jerry PriceAug 31, 2025
    How to clean thick encrustation on the forks of Emerson Rosemount 2120 Switch?
    • T
      Timothy LangAug 31, 2025
      Carefully clean the fork of the Emerson Switch. Consult the Maintenance section for detailed instructions.
  • G
    garrett10Sep 3, 2025
    What to do if my Emerson Rosemount 2120 Switch is not switching?
    • T
      Taylor DunnSep 3, 2025
      If your Emerson Switch isn't switching, there are several potential causes. First, check the power supply, and if it's a direct load switching electronics model, check the load. If the LED is flashing, consult the LED indication section. A damaged fork could also be the problem, in which case you should replace the 2120. If there's thick encrustation on the fork, carefully clean it. Finally, note that a 5-second delay when changing mode/delay is normal, so simply wait 5 seconds.
  • T
    Thomas RobertsonSep 7, 2025
    What to do if my Emerson Rosemount 2120 is switching incorrectly?
    • D
      Dennis BurkeSep 7, 2025
      If your Emerson Switch is switching incorrectly, set the correct mode on the electronics cassette.

Summary

About this guide

Installation

Fork Alignment Options

Explains correct fork alignment for pipe and vessel installations.

Mounting the Threaded Version

Details mounting the threaded version, including sealing and connections.

Threaded Flange Connection

Procedure for installing the level switch with a threaded flange.

Mounting the Flanged Version

Procedure for mounting the flanged version of the level switch.

Mounting the Tri Clamp Version

Procedure for mounting the Tri Clamp version of the level switch.

Prepare Electrical Connections

Cable and Power Specifications

Covers cable selection, glands, power supply, and hazardous area considerations.

Wiring Diagrams Overview

Introduces wiring diagrams for various electronics cassettes.

Connect Wiring and Power-Up

Configuration

Set Output Mode and Time Delay

How to configure the output mode and time delay for the level switch.

Operation

LED Indication

Explains the meaning of LED indicators and their flash rates for operating status.

Servicing and Troubleshooting

Magnetic Test Point Function

How to use the magnetic test point for functional testing of the device.

Maintenance and Inspection Procedures

Guidelines for routine maintenance and visual inspection of the level switch.

Spare Parts Information

Information on obtaining spare parts for the Rosemount 2120 level switch.

Cassette Replacement and Calibration

Procedures for replacing and calibrating electronics cassettes.

Troubleshooting Guide

Guide to identify and resolve common faults and issues with the level switch.

Emerson Rosemount 2120 Specifications

General IconGeneral
TechnologyVibrating Fork
ApplicationLiquid level detection
Housing MaterialAluminum or Stainless Steel
OutputRelay
Process Temperature-40 to 150 °C (-40 to 302 °F)
Process PressureUp to 100 bar (1450 psi)
Wetted Material316L Stainless Steel
Process ConnectionThreaded, Flanged, Hygienic
Ingress ProtectionIP66/67
CertificationsCSA, FM, ATEX, IECEx

Related product manuals