12
Manual Supplement
00809-0400-2410, Rev AA
Rosemount 2410 Tank Hub
March 2016
Rosemount 2410 Tank Hub
3. In the Gauge Type drop-down list select 811 for gauges such as 811, 854, 894, 873
and 973 (TOI B), or select 813 (TOI C).
There are several emulation configuration parameters that can be enabled for
specific settings.
4. Select the desired check boxes to enable specific parameter settings.
See parameter description below.
Disable Tor C Disable Type of Request (TOR) C response (no response on temperature
request).
Water Level Enable Water interface measurement. The level value in TOR B and D, is
replaced with the Water Level value when a TOR W is received.
Ullage Respond with ullage instead of level.
LowRes Pressure Resolution of the pressure value will be decreased by one decimal digit.
MiApproved The level will be invalid if outside the legal level value range and
temperature will be invalid outside legal temperature value range.
HighRes Level Resolution of the level value will be increased by one decimal digit. (Only
applicable for decimal feet and inches.)
Emulate Enraf 873 Respond with device 873 on identification requests.