| Model | RSTi-OM |
|---|---|
| Product Type | Control Unit |
| Manufacturer | Emerson |
| Input Voltage | 24 VDC |
| Output Voltage | 24 VDC |
| Isolation Voltage | 1500 VAC |
| Mounting | DIN Rail |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
Explains warnings about hazardous voltages, currents, temperatures.
Explains cautions about potential equipment damage.
Overview of the IO-Link Master module and its features.
Steps for installing the IOLM hardware, including network and power.
Steps for connecting the IOLM to the network via Ethernet.
Methods for assigning IP addresses (DCP, DHCP, Static).
Procedure to assign the PROFINET IO Device Name via web interface.
Describes different types of IO-Link port modules.
Configuration for IO-Link port cycle time and data storage.
Steps to update IOLM images and application sub-assemblies.
Details the IOLM's eight IO-Link ports and their specifications.
Details current capacity, overload, and short-circuit protection.
Steps to prepare for port configuration, including diagnostics.
Configuration options for IO-Link ports.
How to edit IO-Link device parameters using the port table.
How to reset an IO-Link device to its factory default settings.
How to set up user accounts and passwords for IOLM access.
Explains data storage support and its uses.
Options for device validation (None, Compatible, Identical).
How to use the IO-Link Diagnostics page to check port status.
Details fields on the PROFINET IO Diagnostics page.
Details fields on the Modbus/TCP Diagnostics page.
Guide on reading PDI data from an IO-Link device into a PLC.
How to write PDO data to an IO-Link device from a PLC.
How IO-Link events map to PROFINET alarms and diagnostics.
Lists the supported Modbus function codes.
Definitions of Modbus/TCP interface addresses.
Explains how to access PDI/PDO data for multiple ports via Modbus/TCP.
Overview of the MQTT settings configuration page.
Controls how often PDI/PDO messages are published.
Descriptions of process data blocks for Modbus/TCP.
Illustrates the process of clearing events after a hold time.
Explains the structure of ISDU request and response messages.
Provides steps to resolve common issues before contacting technical support.
Explains the meaning of each LED state and color on the IOLM.
Procedure to view different types of log files.
Using a splitter to inject additional input signals.
How to connect power to Class B IO-Link devices using a splitter.