66
Reference Manual
00809-0100-4825, Rev CB
Appendix B: Product Certifications
March 2014
Product Certifications
I5 FM Intrinsic Safety and Nonincendive
Certificate: 3016555
Standards Used: FM Class 3600:1998, FM Class 3610:2010, FM Class 3611:2004, FM Class
3810:2005, ANSI/ISA 60079-0:2009, ANSI/ISA 60079-11:2009, IEC 60529: 2001, NEMA -
250: 1991
Markings: IS CL I/II/III, DIV 1, GP A, B, C, D, E, F, G; NI CL1, DIV 2, GP A, B, C, D T6(-40°C
T
a
+40 °C), T5(-40 °C T
a
+75 °C) when installed per Rosemount drawing 00248-1055;
Type 4X; IP66/68
Special Conditions for Safe Use (X):
1. When no enclosure option is selected, the Model 248 Temperature Transmitter shall
be installed in an enclosure meeting the requirements of ANSI/ISA S82.01 and S82.03
or other applicable ordinary location standards
2. No enclosure or Buz Head option cannot be selected to maintain a Type 4X rating
3. Enclosure option must be selected to maintain a Type 4 Rating
I6 CSA Intrinsic Safety and Division 2
Certificate: 1091070
Standards Used: CAN/CSA C22.2 No. 0-M90, CSA Std. C22.2 No. 25-1966, CAN/CSA C22.2
No. 94-M91, CAN/CSA C22.2 No. 157-92, CSA C22.2 No. 213-M1987, C22.2 No 60529-05
Markings: IS CL I, DIV 1 GP A, B, C, D when installed per Rosemount drawing 00248-1056;
Suitable for CL I DIV 2 GP A, B, C, D when installed per Rosemount drawing 00248-1055;
T6(-50 °C
T
a
+40 °C), T5(-50 °C T
a
+60 °C); Type 4X, IP66/68 for enclosure options
A”, “G”, “H”, “U”; Seal not required (See drawing 00248-1066)
K6 CSA Explosionproof, Intrinsic Safety, and Division 2
Certificate: 1091070
Standards Used: CAN/CSA C22.2 No. 0-M90, CSA Std. C22.2 No. 25-1966, CSA Std. C22.2
No. 30-M1986, CAN/CSA C22.2 No. 94-M91, CSA Std. C22.2 No.142-M1987, CAN/CSA
C22.2 No. 157-92, CSA C22.2 No. 213-M1987, C22.2 No 60529-05
Markings: XP CL I/II/III, DIV 1, GP B, C, D, E, F, G when installed per Rosemount drawing
00248-1066; IS CL I, DIV 1 GP A, B, C, D when installed per Rosemount drawing
00248-1056; Suitable for CL I DIV 2 GP A, B, C, D when installed per Rosemount drawing
00248-1055; T6(-50 °C
T
a
+40 °C), T5(-50 °C T
a
+60 °C); Type 4X, IP66/68 for
enclosure options “A”, “G”, “H”, “U”; Seal not required (See drawing 00248-1066)
B.3.2 Europe
E1 ATEX Flameproof
Certificate: FM12ATEX0065X
Standards Used: EN 60079-0: 2012, EN 60079-1: 2007, EN 60529:1991 +A1:2000
Markings: II 2 G Ex d IIC T6…T1 Gb, T6(-50 °C
T
a
+40 °C), T5…T1(-50 °C T
a
+60 °C);
See Tab le B -1 at the end of the Product Certifications section for Process Temperatures