accordance with control drawing 9240030-936; -50 °C ≤ Ta ≤ 60
°C / 70 °C; Type 4X
Special Conditions for Safe Use (X):
1. WARNING – Potential Electrostatic Charging Hazard – The enclosure
contains non-metallic material. To prevent the risk for electrostatic
sparking the plastic surface should only be cleaned with a damp cloth.
2. WARNING – The apparatus enclosure contains aluminum and is
considered to constitute a potential risk of ignition by impact or
friction. Care must be taken into account during installation and use to
prevent impact or friction.
Ui Ii Pi Ci Li
FISCO parameters 17.5 V 380 mA 5.32 W 0 0
9.6 Canada
9.6.1 E6 Explosionproof, Dust-Ignitionproof
Certificate
1514653
Standards
CSA C22.2 No.0-M91, CSA C22.2 No.25-1966, CSA C22.2
No.30-M1986, CSA C22.2 No.94-M91, CSA C22.2 No.142-
M1987, CSA C22.2 157-92, CAN/CSA C22.2 No. 60529:05,
ANSI/ISA 12.27.01-2003
Markings
Explosionproof CL I, DIV 1, GP B, C, D; Dust-Ignitionproof CL II,
DIV 1 and 2, GP E, F, G and coal dust, CL III, DIV 1, Type 4X/IP66/
IP67
9.6.2 I6 Intrinsically Safe and Non-Incendive Systems
Certificate
1514653
Standards
CSA C22.2 No.0-M91, CSA C22.2 No.25-1966, CSA C22.2
No.30-M1986, CSA C22.2 No.94-M91, CSA C22.2 No.142-
M1987, CSA C22.2 157-92, CAN/CSA C22.2 No. 60529:05,
ANSI/ISA 12.27.01-2003
Markings
CL I, DIV 1, GP A, B, C, D, T4 see installation drawing
9240030-937; Non-Incendive Class III, DIV 1, Haz-loc CL I DIV 2,
GP A, B, C, D, Maximum Ambient Temperature +60 °C for
Fieldbus and FISCO and +70 °C for HART, T4, Type 4X/IP66/
IP67, Maximum Working Pressure 5000 psi, Dual Seal.
February 2019 Quick Start Guide
Quick Start Guide 31