CAUTION
The sensor liner is vulnerable to handling damage. Liner damage can
render the sensor useless. Failure to observe these instructions could
result in severe damage to the sensor lining and possible sensor
replacement.
To avoid possible damage to the sensor liner ends:
Do not use metallic or spiral-wound gaskets. If spiral wound or
metallic gaskets are required for the application, lining protectors
must be used.
If frequent removal is anticipated, attach short spool pieces to the
sensor ends.
Tighten bolts in the proper sequence to the specified torque limits.
Correct flange bolt tightening is crucial for proper sensor operation
and life.
In cases where high voltage/high current are present near the meter
installation, ensure proper protection methods are followed to prevent
stray voltage/current from passing through the meter. Failure to
adequately protect the meter could result in damage to the transmitter
and lead to meter failure.
Completely remove all electrical connections from both sensor and
transmitter prior to welding on the pipe. For maximum protection of the
sensor, consider removing it from the pipeline.