4 Sensor Installation
4.1 Flanged sensors
Gaskets
The sensor requires a gasket at each process connection. The gasket
material must be compatible with the process fluid and operating
conditions. Gaskets are required on each side of a grounding ring (see Figure
4-1). All other applications (including sensors with lining protectors or a
grounding electrode) require only one gasket on each process connection.
Note
Metallic or spiral-wound gaskets should not be used as they will damage the
liner face of the sensor. If spiral wound or metallic gaskets are required for
the application, lining protectors must be used.
Figure 4-1: Gasket placement for flanged sensors
A
B
A. Grounding ring and gasket (optional)
B. Customer-supplied gasket
Quick Install Guide November 2019
12 Rosemount
MS Slurry Magnetic Flow Meter Sensor