Sensi smart thermostat | HUMIDITY GUIDE 4
3. CONFIGURATION – SETTING HUMIDIFICATION/DEHUMIDIFICATION CONTROL CAPABILITY ON/OFF
CONFIGURATION MENU ITEMS REFERENCE
Display
Code
Menu item Default Options
Wireless setup
Connects thermostat to wi-fi network
Connect
Fahrenheit or celsius F
F
C
Outdoor equipment configuration
Cooling or heat pumps
AC2
AC1 – Conventional cooling 1 (single-stage)
AC2– Conventional cooling 2 (two-stage)
HP1 – Heat pump 1 (single-stage)
HP2 – Heat pump 2 (two-stage)
AC0 – No cooling
Indoor equipment configuration
For gas or electric heat
EL2
EL1– Electric 1 (single-stage)
EL2– Electric 2 (two-stage)
FAn
GA1 – Gas 1 (single-stage)
GA2 – Gas 2 (two-stage)
Reversing valve position
Selects “O” or “B” setting
For heat pumps only
O
O
B
2
Fn Circulating fan OFF Off/10% – 100% (5% increments)
H AA
Humidification
Add accessory
OFF Off/On
H SP
Humidification
Set point
OFF Off/5% – 50% (5% increments)
dH AA
Dehumidification
Add accessory
Od
Od/Oc
Od – Optimal dehumidification
(overcool to dehumidify)
Oc – Optimal comfort (wired dehumidification)
dH SP
Dehumidification
Set point
OFF Off/40% – 95% (5% increments)
Wireless radio
Turns wi-fi radio on/off
ON Off/On