Features and Specications
ER 5000 Specifications
Contact the factory for dimensions and specications of models ER5020, ER5040, ER5100 and ER5110. Refer to the ER5000 Series Part Numbering System.
Enclosure
Type 4X, IP66. If the two 1/2-14 NPTF ports are unused, properly
seal with a plug.
CE Approved Wiring Instructions
Use shielded, twisted pair cable.
Weight
3.1 lbs / 1.4 kg
Media
Supply pressure must be clean, dry inert gas or instrument grade
air that meets the requirements of ISA Standard 7.0.01. Use of an
in-line lter that meets the requirements of ISA standard 7.0.01
and is less than 40 microns and as small as 10 microns, is highly
recommended to prevent damage to the solenoid valves. Moisture
should be kept to a minimum.
Ports
Conduit: 1/2" NPTF
Pneumatic: 1/8" NPTF — Inlet, Exhaust and Gauge Ports
1/2" SAE — Controlled Outlet Port
Power Requirement
Voltage: 24V DC (22V DC to 28V DC)
Current: 340 mA max, 180 mA nominal
Environment
Temperature: -30°C to 75°C (dry Nitrogen supply gas)
5°C to 75°C (shop air)
Pressure: 28" to 32
" Hg / 71 mm to 762 mm Hg
Humidity: To 100% R.H. (non-condensing) @ 0°C to 75°C.
Inlet Pressure
Minimum: Outlet pressure + 1 psig
Maximum: 120 psig / 8.2 bar
Typical: 110 psig / 7.5 bar
NOTENOTE
CAUTIONCAUTION
WARNINGWARNING
Response time is affected by input pressure.
Sensor Update Rate
25ms (rate of sensor reading and processing task)
USB Communication Interface
USB: 2.0
Maximum cable length: 15 ft / 4.5 m
Connector: Mini-B