24 Unidrive M700/M701 / Unidrive HS70/HS71 Control Getting Started Guide
Issue Number: 2
Figure 4-6 Basic NV Media Card operation
The whole card may be protected from writing or erasing by setting the read-only flag, refer to the
Drive User Guide for further information.
The card should not be removed during data transfer, as the drive will produce a trip. If this occurs
then either the transfer should be reattempted or in the case of a card to drive transfer, default
parameters should be loaded.
Pr = Read +00.030
Drive reads all
parameters from
the NV Media Card
Pr = Program +00.030
Programs all drive
parameters to the
NV Media Card
NOTE
Overwrites any
data already in
data block 1
Pr = Auto +00.030
Auto
Save
Drive automatically
writes to the
when a parameter
save is performed
Media Card
Pr = Boot +00.030
Boot
Auto Save
Drive boots from the
NV Media Card on
power up and
automatically writes
to the
when a parameter
save is performed
Media Card
Unidrive M700_M701 Getting Started Guide English iss7.book Page 24 Friday, December 12, 2014 1:14 PM