28 Unidrive M700/M701 / Unidrive HS70/HS71 Control Getting Started Guide
Issue Number: 2
1
RW = Read Write, RO = Read Only.
* Only applicable to Unidrive M701/HS71.
** Only applicable to Unidrive M700/HS70.
00.043
Rated Power Factor 0.000 to 1.000 0.850
RW
Position Feedback Phase
Angle
0.0 to 359.9 °
RW
00.044 Rated Voltage ±VM_AC_VOLTAGE_SET
200 V drive: 230 V
50 Hz default 400 V drive: 400 V
60 Hz default 400 V drive: 460 V
575 V drive: 575 V
690 V drive: 690 V
RW
00.045
Uni M: Rated Speed
0 to
33,000 rpm
0.00 to
33,000.00
rpm
50Hz
default:
1500 rpm
60Hz
default:
1800rpm
50Hz
default:
1450 rpm
60Hz
default:
1750rpm
RW
Uni HS: Rated Speed
0 to
180,000 rpm
0 to
50,000 rpm
Motor Thermal Time
Constant 1
1.0 to
3000.0 s
89.0 s
RW
00.046 Rated Current ±VM_RATED_CURRENT
Maximum Heavy Duty Rating
(11.032)
RW
00.047
Uni M: Rated Frequency 0.0 to 550.0 Hz
50Hz default: 50.0 Hz
60Hz default: 60.0 Hz
RW
Uni HS: Rated Frequency 0.0 to 3000 Hz
0.0 to
1667 Hz
00.048 Drive Mode
Open-loop (1), RFC-A (2),
RFC-S (3), Regen (4)
Open-loop
(1)
RFC-A
(2)
RFC-S
(3)
RW
00.049 User Security Status
Menu 0 (0), All Menus (1),
Read-only Menu 0 (2), Read-only (3),
Status Only (4), No Access (5)
Menu 0 (0)
RW
00.050 Software Version 0 to 99999999
RO
00.051 Action On Trip Detection 0 to 31 0
RW
00.052
Reset Serial
Communications*
Off (0) or On (1) Off (0)