Unidrive M100-101 Quick Start Guide 25
Issue Number: 6
10
AT ZERO FREQUENCY
RUN
REVERSE
RUN
FORWARD
Minimum
Reference
Reference
Clamp
00.001
00.002
12 13
Ramps
Acceleration
Rate 1
Deceleration
Rate 1
Ramp Mode
Select
00.003
00.004
00.028
Maximum
Low
Frequency
Voltage
Boost
Clamp
Digital output
Power stage
_
+
_
+
U
V
W
Resistor
optional
Drive
00.037
05.001
Maximum Switching
Frequency
Output Frequency
Torque
Producing
Current
Current
Magnitude
Magnetising
Current
+
BR
_
04.002
04.001
L3L2L1
00.033
Power Factor
Rated Voltage
Rated Speed
Rated Current
00.006 ~ 00.009
Motor
parameters
04.011
Torque Mode
Selector
Unidrive M100 101 Quick Start Guide English Iss6.book Page 25 Wednesday, September 9, 2015 4:07 PM