34 Unidrive M200/201 Control Quick Start Guide
Issue Number: 2
This parameter selects the function of Digital Input 5.
Defines the behaviour of digital output 1.
00.034 {08.005} Digital Input 5 Mode
RW Txt US
OL
Ú
Input (0), th.Sct (1), th (2), th.Notr 
(3), Fr (4)
Ö
Input (0)
RFC-A
Value Text Function
0 Input (0) Digital input
1th.Sct (1)
Temperature measurement input with short circuit detection
(Resistance <50 Ω )
2th (2)
Temperature measurement input without short circuit detection but 
with th trip
3 th.Notr (3) Temperature measurement input with no trips
4 Fr (4) Frequency input
00.035 {08.091} DO1 Control (terminal 10)
RW Num US
OL
Ú
0-21
Ö
0
RFC-A
Value Description
0
User defined by Digital IO1 Source/Destination A, Digital IO2 Source/Destination A, 
Relay 1 Output Source A, or Relay 2 Output Source A. 
1 Drive running signal (RUN)
2 Frequency arrived signal (FAR)
3 Frequency level detection signal (FDT1)
4 Frequency level detection signal (FDT2)
5 Overload detection signal (OL)
6 Power off state (LU)
7 External fault stop (EXT)
8 Frequency upper limit (FHL)
9 Frequency lower limit (FLL)
10 Drive running at zero frequency
14 Drive (RDY)
15 Drive OK
18 Brake release
19 Torque limiting (Valid while the torque is limited by torque limiting value 1/2)
20 Forward or reverse
21 Motor 1 or 2