40 Unidrive M200/201 Control Quick Start Guide
Issue Number: 2
Defines the initial direction of the brake.
See Brake Controller Brake Release in Drive User Guide.
Defines if the brake is applied through zero threshold. See Brake Controller Brake Release in Drive
User Guide.
If Brake Controller Enable (00.055) = 0, the brake controller is disabled.
If Brake Controller Enable (00.055) = 1, the brake controller is enabled with I/O set up to control the
brake via the relay output. Drive ok is re-routed to digital I/O.
If Brake Controller Enable (00.055) = 2, the brake controller is enabled with I/O set up to control the
brake via digital I/O. Drive ok is routed to the relay output.
If Brake Controller Enable (00.055) = 3, the brake controller is enabled, but no parameters are set up
to select the brake output.
00.053 {12.047} Brake Controller Initial Direction
RW Txt US
OL
Ú
Ref (0), For (1), Rev (2)
Ö
Ref (0)
RFC-A
Value Text
0reF
1For
2Rev
00.054 {12.051} Brake Controller Brake Apply Through Zero Threshold
RW Num US
OL
Ú
0.00 to 25.00 Hz
Ö
0.00 Hz
RFC-A
00.055 {12.041} Brake Controller Enable
RW Txt US
OL
Ú
dis (0), Relay (1), dig IO (2), User (3)
Ö
dis (0)
RFC-A
Value Text
0Dis
1 Relay
2 dig IO
3 USEr