Spin Start Boost (00.069) is used by the algorithm that detects the frequency of a spinning motor 
when the drive is enabled and Catch A Spinning Motor (00.033) ≥ 1. For smaller motors the default 
value of 1.0 is suitable, but for larger motors Spin Start Boost (00.069) may need to be increased. 
If Spin Start Boost (00.069) is too small the drive will detect zero speed whatever the frequency of the 
motor, and if Spin Start Boost (00.069) is too large the motor may accelerate away from standstill 
when the drive is enabled.
Bit 0: Stop on defined non-important trips
Bit 1: Disable braking resistor overload detection
Bit 2: Disable phase loss stop
Bit 3: Disable braking resistor temperature monitoring
Bit 4: Disable parameter freeze on trip. Refer to Drive User Guide.
Displays the maximum heavy duty current rating of the drive.
Displays the software version in the drive.
Defines the mode of the drive.
00.069 {05.040} Spin Start Boost
RW Num US
OL
Ú
0.0 to 10.0
Ö
1.0
RFC-A
00.076 {10.037} Action On Trip Detection
RW Num ND NC PT US
OL
Ú
0 - 31
Ö
0
RFC-A
00.077 {11.032} Maximum Heavy Duty Rating
RO Num ND NC PT
OL
Ú
0.00 to 9999.99 A
Ö
RFC-A
00.078 {11.029} Software Version
RO Num ND NC PT
OL
Ú
0 to 999999
Ö
RFC-A
00.079 {11.031} User Drive Mode
RW Txt ND NC PT US
OL
Ú
OPEn.LP (1), RFC-A (2)
Ö
OPEn.LP (1)
RFC-A RFC-A (2)
Unidrive M200_201 Control Quick Start Guide English Iss1.book  Page 42  Wednesday, September 16, 2015  10:31 AM