20 SI-Ethernet User Guide
Issue: 1
5.10 Single line parameter descriptions
Table 5.3 lists the coding used for the parameter type in the subsequent parameter description
tables.
Table 5.3 Parameter type coding
5.10.1 Menu 0 - Ethernet set-up (MM.ppp)
Table 5.4 Menu 0 parameters
Menu 0 within the Ethernet interface, is also displayed in the drive menu 15, 16, 17 or 24 depending
on which slot the option module is installed to and the setting of the Option Slot Identifiers
parameter (S.11.056).
By default, the SI-Ethernet option module will be either menu 15, 16 or 17 and the onboard
Ethernet interface will be menu 24.
Table 5.5 Menu 0 slot availability details the drive models and their available slots and associated
drive menus for use with both the SI-Ethernet option module and the onboard Ethernet interface.
Table 5.5 Menu 0 slot availability
RW
Read /
Write
RO Read-only Bit
Bit
parameter
Txt Text string Date
Date
parameter
Time
Time
parameter
Chr
Character
parameter
Bin
Binary
parameter
IP IP address Mac
MAC
address
Ver
Version
number
SMP
Slot, menu,
parameter
Num
Number
parameter
DE Destination ND
No default
value
RA
Rating
dependent
NC
Non-
copyable
PT Protected
FI Filtered US User save PS
Power-
down save
Parameter Range Default Type
00.001 Module ID 0 to 65535 RO Num ND NC PT
00.002 Software Version 00.00.00.00 to 00.99.99.99
RO Ver ND NC PT
00.003 Hardware Version 0.00 to 99.99
RO Num ND NC PT
00.004 Serial Number LS 00000000 to 99999999
RO Num ND NC PT
00.005 Serial Number MS 0 to 99999999
RO Num ND NC PT
00.006 Status
Bootldr - Update (-2),
Bootldr - Idle (-1),
Initializing (0),
OK (1),
Config (2),
Error (3)
RO Txt ND NC PT
00.007 Reset Off (0) or On (1) Off (0) RW Bit NC
00.008 Default Off (0) or On (1) Off (0) RW Bit NC
00.009 Active Alarm Bits
0000000000000000 to
1111111111111111
0000000000000000 RO Bin NC
00.010 Active IP Address
128.0.0.0 to
127.255.255.255
0.0.0.0 RO IP NC PT