42 SI-Ethernet User Guide
Issue: 1
The module’s active IP address.
6.1.2 Menu 2 - Ethernet configuration
This parameter indicates the status of the network that the module is connected to.
This parameter displays the number of frames that the module is transmitting and/or
receiving every second.
S.00.010 Active IP Address
Minimum
-2147483648
(Display:128.0.0.0)
Maximum
2147483647
(Display:127.255.255.255)
Default
0
(Display: 0.0.0.0)
Units
Type 32 Bit Volatile Update Rate Background
Display Format IP Address Decimal Places 0
Coding RO, NC, PT
S.02.003 Network Status
Minimum 0 Maximum 5
Default Units
Type 8 Bit Volatile Update Rate Written every second
Display Format None Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
Value Text Description
0 Initialising The network interface is being initialized
1Links Down
No link connection has been detected on either of the Ethernet
ports
2
DHCP In
Progress
The module is attempting to obtain the IP address, subnet
mask, default gateway and DNS server addresses from a
DHCP server
3 No Address
The module does not have an IP address - either the user has
not provided one manually or one could not be allocated via
DHCP
4 Ready
The network interface has been successfully configured but no
data is being received or transmitted
5 Active The network interface is receiving or transmitting data
S.02.004 Network Message Count
Minimum 0 Maximum 65535
Default Units Messages/s
Type 16 Bit Volatile Update Rate Written every second
Display Format None Decimal Places 0
Coding RO, ND, NC, PT, BU