The web server port. This may be changed for added security.
Specifies the MTU (Maximum Transmittable Unit) in bytes allowed by the Ethernet
interface.
Specifies the operation mode of the gateway. By default the gateway is disabled and the
switch operates in normal switch mode. By enabling the gateway mode all packets are
filtered by the module and prioritized before being forwarded on. In strict mode the
gateway will drop packets from unsupported protocols.
S.02.022 Web Server Port
Minimum 0 Maximum 65535
Default 80 Units
Type 1 Bit User Save Update Rate
Read on module reset
and HTTP_ENABLE
Display Format None Decimal Places 0
Coding RW, BU
The web server functionality is not currently implemented.
S.02.024 Ethernet MTU
Minimum 158 Maximum 1500
Default 1500 Units Bytes
Type 16 Bit User Save Update Rate Read on module reset
Display Format None Decimal Places 0
Coding RW, BU
S.02.025 Gateway Mode
Minimum 0 Maximum 2
Default 0 Units
Type 8 Bit User Save Update Rate Read on module reset
Display Format None Decimal Places 0
Coding RW, TE, BU
NOTE
Value Text
0Switch
1 Gateway
2 Strict Gateway