54 SI-Ethernet User Guide
Issue: 1
This parameter allows the protocol to be defaulted to factory settings. This includes all
of the protocol features, configuration, mappings and stored objects.
Used to select Tx1 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Tx1 link.
This parameter sets the source parameter for the Tx1 link.
S.10.003 Default
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit Volatile Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, NC
S.10.010 Tx1 Link Profile
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE
Value Text Description
0
Std Standard link
1
Sync Synchronized link
S.10.011 Tx1 Link Number
Minimum 0 Maximum 255
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
S.10.012 Tx1 Source Parameter
Minimum
0
(Display:0.00.000)
Maximum
499999
(Display: 4.99.999)
Default
0
(Display:0.00.000)
Units
Type 32 Bit User Save Update Rate Read on reset
Display Format Slot Menu Param Decimal Places 0
Coding RW, PT, BU