What to do if emmeti EH1018DC Heat Pump shows AL09 error (Water flow rate to the HP too low)?
C
Cameron VelazquezAug 16, 2025
If the emmeti Heat Pump displays error code AL09 indicating a low water flow rate, first check the pressure and water circulation within the system. Secondly, inspect the water filter and clean it if necessary.
D
douglasboydAug 19, 2025
What to do if emmeti EH1018DC Heat Pump shows AL07 error (Low water temp value)?
H
Howard ThomasAug 19, 2025
If the emmeti Heat Pump displays error code AL07 indicating a low water temperature, first check the pressure and water circulation in the system. Second, manually reset the HP by switching it off and on again after a few minutes, then monitor its operation.
A
amy57Aug 21, 2025
What to do if emmeti EH1018DC shows AL10 error (Low system pressure)?
K
Karen TownsendAug 22, 2025
If the emmeti Heat Pump displays error code AL10 indicating low system pressure, check the water pressure in the system.
S
Sean CallahanAug 25, 2025
What to do if emmeti EH1018DC Heat Pump shows AL01 error (Abnormal value of the water inlet temp to the HP)?
H
hunterbrendaAug 26, 2025
If the emmeti Heat Pump displays error code AL01 indicating an abnormal water inlet temperature, first check the sensor connection to the PCB TERMINAL BLOCK. If the issue persists, replace the sensor. If the problem still occurs, replace the SMART-MT.
N
Nicholas AlexanderAug 27, 2025
What to do if emmeti Heat Pump shows AL12 error (Abnormal value of the AMBIENT Temp. From Febos Chrono)?
T
Todd KnightAug 27, 2025
If the emmeti Heat Pump displays error code AL12, indicating an abnormal ambient temperature from Febos Chrono, follow these steps:
1. Check the connection of the humidity sensor to the FEBOS CRONO MASTER (if AL13).
2. Check the connection of the FEBOS CRONO MASTER to the PCB TERMINAL BLOCK.
3. Replace the FEBOS CRONO MASTER.
4. Replace the SMART-MT.
K
Keith MeyerAug 30, 2025
What to do if emmeti Heat Pump shows AL11 error (Failed / incorrect communication with Febos Crono (Master))?
J
Joshua AdamsAug 30, 2025
If the emmeti Heat Pump displays error code AL11 indicating a communication failure with Febos Crono (Master), follow these steps:
1. Check the connection of the Febos Crono Master to the PCB TERMINAL BLOCK.
2. Replace the Febos Chrono Master.
3. Replace the SMART-MT.
E
Emily OrtizSep 2, 2025
What to do if emmeti EH1018DC Heat Pump shows AL14 error (Stagione incongruente (SMART-MT / Febos-Crono))?
F
Francis KellySep 2, 2025
If the emmeti Heat Pump displays error AL14, which indicates 'Stagione incongruente', change the season setting on Febos-Crono or entrance 104 (G+ / G-) della PCB TERMINAL BLOCK.
J
Jeffrey WintersSep 4, 2025
Why is the pump running while my emmeti EH1018DC Heat Pump is stopped?
A
Aaron McdowellSep 4, 2025
The circulation pump operates automatically at times to prevent scale build-up on the pipe walls or for antifreeze protection.
A
Albert MaxwellSep 7, 2025
What to do if I hear the sound of water in the pipes of my emmeti Heat Pump?
S
Steven HughesSep 7, 2025
To resolve the sound of water in the pipes of your emmeti Heat Pump, vent the air from the system and refill it with water.
K
Kenneth WilkinsSep 10, 2025
Why does steam escape from my emmeti Heat Pump?
C
Christian CurtisSep 10, 2025
Steam escaping from the emmeti Heat Pump is caused by the unit defrosting during heating operation.