Questions and Answers

  • C
    charlesyoungAug 16, 2025
    What to do if emmeti EH1718D3 shows AL09 error (Water flow rate to the HP too low)?
    • A
      Andrew GonzalesAug 17, 2025
      If the emmeti Heat Pump displays error code AL09 indicating a low water flow rate, first check the pressure and water circulation within the system. Secondly, inspect the water filter and clean it if necessary.
  • P
    Paul ThomasAug 19, 2025
    What to do if emmeti Heat Pump shows AL07 error (Low water temp value)?
    • C
      Carol FarmerAug 19, 2025
      If the emmeti Heat Pump displays error code AL07 indicating a low water temperature, first check the pressure and water circulation in the system. Second, manually reset the HP by switching it off and on again after a few minutes, then monitor its operation.
  • N
    Nicole MillerAug 21, 2025
    What to do if emmeti Heat Pump shows AL10 error (Low system pressure)?
    • T
      Tamara SimsAug 22, 2025
      If the emmeti Heat Pump displays error code AL10 indicating low system pressure, check the water pressure in the system.
  • T
    Teresa HardyAug 25, 2025
    What to do if emmeti Heat Pump shows AL01 error (Abnormal value of the water inlet temp to the HP)?
    • E
      Eric ByrdAug 26, 2025
      If the emmeti Heat Pump displays error code AL01 indicating an abnormal water inlet temperature, first check the sensor connection to the PCB TERMINAL BLOCK. If the issue persists, replace the sensor. If the problem still occurs, replace the SMART-MT.
  • N
    Nicholas HuntAug 27, 2025
    What to do if emmeti EH1718D3 shows AL12 error (Abnormal value of the AMBIENT Temp. From Febos Chrono)?
    • L
      Lindsay EdwardsAug 27, 2025
      If the emmeti Heat Pump displays error code AL12, indicating an abnormal ambient temperature from Febos Chrono, follow these steps: 1. Check the connection of the humidity sensor to the FEBOS CRONO MASTER (if AL13). 2. Check the connection of the FEBOS CRONO MASTER to the PCB TERMINAL BLOCK. 3. Replace the FEBOS CRONO MASTER. 4. Replace the SMART-MT.
  • J
    Janet VincentAug 30, 2025
    What to do if emmeti EH1718D3 shows AL11 error (Failed / incorrect communication with Febos Crono (Master))?
    • C
      christinaperezAug 30, 2025
      If the emmeti Heat Pump displays error code AL11 indicating a communication failure with Febos Crono (Master), follow these steps: 1. Check the connection of the Febos Crono Master to the PCB TERMINAL BLOCK. 2. Replace the Febos Chrono Master. 3. Replace the SMART-MT.
  • E
    Ethan YorkSep 1, 2025
    What to do if emmeti Heat Pump shows AL14 error (Stagione incongruente (SMART-MT / Febos-Crono))?
    • L
      Luis GreenSep 2, 2025
      If the emmeti Heat Pump displays error AL14, which indicates 'Stagione incongruente', change the season setting on Febos-Crono or entrance 104 (G+ / G-) della PCB TERMINAL BLOCK.
  • K
    kvalentineSep 4, 2025
    Why is the pump running while my emmeti EH1718D3 is stopped?
    • Y
      ybergerSep 4, 2025
      The circulation pump operates automatically at times to prevent scale build-up on the pipe walls or for antifreeze protection.
  • V
    vbookerSep 7, 2025
    What to do if I hear the sound of water in the pipes of my emmeti EH1718D3?
    • R
      Ronnie WilliamsSep 7, 2025
      To resolve the sound of water in the pipes of your emmeti Heat Pump, vent the air from the system and refill it with water.
  • L
    linda42Sep 10, 2025
    Why does steam escape from my emmeti EH1718D3?
    • J
      joneskeithSep 12, 2025
      Steam escaping from the emmeti Heat Pump is caused by the unit defrosting during heating operation.

Summary

Technical Specifications Overview

Detailed Technical Data

Provides detailed technical specifications for various operating conditions.

Operational Ranges and Circulator Performance

Safety Warnings and Precautions

Refrigerant R32 Safety Data Sheet

Safety information, properties, first aid, fire fighting, and disposal of R32 refrigerant.

General Usage and Installation Warnings

General prohibitions and dangers related to unit operation and installation.

Prohibitions and Warnings for Installation

Specific prohibitions and warnings for installing the heat pump safely.

Installation Procedures and Requirements

Hydraulic and Electrical System Installation

Covers hydraulic connections, water charge, electrical system, and wiring.

Installation Type Diagrams

SMART MT Controller Operation

Parameter Settings and Time Configuration

Guide to accessing and changing parameters, and setting the system time.

User Section: System Operation

Advanced Operation Modes and Alarms

Parallel/alternate operation, alarms, electrical power monitoring, and error handling.

Alarm Codes and Troubleshooting

Troubleshooting Common Issues

General troubleshooting steps for common unit problems.

SMART MT Alarm Codes and Resets

Detailed list of SMART-MT alarm codes and manual reset procedures.

PCB Alarm Codes - Electrical Issues

PCB alarm codes related to electrical supply, fuses, voltage, and sensors.

PCB Alarm Codes - Component and System Errors

PCB alarm codes for motors, PCB errors, and system malfunctions.

Service and Maintenance Procedures

Electrical Component Testing Methods

Procedures for testing fuses, fan motor, and pump voltages.

Wiring Diagrams by Model

EH0618 DC Wiring Diagram

Detailed wiring diagram for the EH0618DC model.

EH1018 DC Wiring Diagram

Detailed wiring diagram for the EH1018DC model.

Product Data Sheets

emmeti EH1718D3 Specifications

General IconGeneral
Brandemmeti
ModelEH1718D3
CategoryHeat Pump
LanguageEnglish

Related product manuals