MIRAI - SMI 4.0
System Manager Integrated
EH0618DC / EH1018DC / EH1218DC / EH1618DC / EH1718D3
Rev. G - 03.2022
MANUALE INSTALLAZIONE ED USO
IT
INSTALLATION AND USE MANUAL
GB

Questions and Answers

  • M
    Michael Barry Jr.Aug 16, 2025
    What to do if emmeti Heat Pump shows AL09 error (Water flow rate to the HP too low)?
    • J
      Jillian SullivanAug 16, 2025
      If the emmeti Heat Pump displays error code AL09 indicating a low water flow rate, first check the pressure and water circulation within the system. Secondly, inspect the water filter and clean it if necessary.
  • D
    Dustin GomezAug 19, 2025
    What to do if emmeti EH1218DC shows AL07 error (Low water temp value)?
    • B
      Becky CoxAug 19, 2025
      If the emmeti Heat Pump displays error code AL07 indicating a low water temperature, first check the pressure and water circulation in the system. Second, manually reset the HP by switching it off and on again after a few minutes, then monitor its operation.
  • J
    Jason GrossAug 22, 2025
    What to do if emmeti EH1218DC shows AL10 error (Low system pressure)?
    • M
      Mrs. Christina MorrisAug 22, 2025
      If the emmeti Heat Pump displays error code AL10 indicating low system pressure, check the water pressure in the system.
  • A
    Amy SchneiderAug 25, 2025
    What to do if emmeti EH1218DC Heat Pump shows AL01 error (Abnormal value of the water inlet temp to the HP)?
    • D
      Dr. Amanda RosarioAug 26, 2025
      If the emmeti Heat Pump displays error code AL01 indicating an abnormal water inlet temperature, first check the sensor connection to the PCB TERMINAL BLOCK. If the issue persists, replace the sensor. If the problem still occurs, replace the SMART-MT.
  • A
    Ashley WheelerAug 27, 2025
    What to do if emmeti EH1218DC shows AL12 error (Abnormal value of the AMBIENT Temp. From Febos Chrono)?
    • T
      Tanner DavidsonAug 27, 2025
      If the emmeti Heat Pump displays error code AL12, indicating an abnormal ambient temperature from Febos Chrono, follow these steps: 1. Check the connection of the humidity sensor to the FEBOS CRONO MASTER (if AL13). 2. Check the connection of the FEBOS CRONO MASTER to the PCB TERMINAL BLOCK. 3. Replace the FEBOS CRONO MASTER. 4. Replace the SMART-MT.
  • K
    kenneth40Aug 30, 2025
    What to do if emmeti EH1218DC shows AL11 error (Failed / incorrect communication with Febos Crono (Master))?
    • S
      Scott MunozAug 30, 2025
      If the emmeti Heat Pump displays error code AL11 indicating a communication failure with Febos Crono (Master), follow these steps: 1. Check the connection of the Febos Crono Master to the PCB TERMINAL BLOCK. 2. Replace the Febos Chrono Master. 3. Replace the SMART-MT.
  • S
    Scott LawrenceSep 1, 2025
    What to do if emmeti EH1218DC Heat Pump shows AL14 error (Stagione incongruente (SMART-MT / Febos-Crono))?
    • L
      lmillerSep 2, 2025
      If the emmeti Heat Pump displays error AL14, which indicates 'Stagione incongruente', change the season setting on Febos-Crono or entrance 104 (G+ / G-) della PCB TERMINAL BLOCK.
  • J
    Jessica BeckerSep 4, 2025
    Why is the pump running while my emmeti EH1218DC is stopped?
    • D
      danielmyersSep 4, 2025
      The circulation pump operates automatically at times to prevent scale build-up on the pipe walls or for antifreeze protection.
  • R
    Richard SalinasSep 7, 2025
    What to do if I hear the sound of water in the pipes of my emmeti Heat Pump?
    • M
      Mary HuberSep 8, 2025
      To resolve the sound of water in the pipes of your emmeti Heat Pump, vent the air from the system and refill it with water.
  • C
    cruzraymondSep 10, 2025
    Why does steam escape from my emmeti EH1218DC?
    • R
      Richard ConwaySep 12, 2025
      Steam escaping from the emmeti Heat Pump is caused by the unit defrosting during heating operation.

Summary

2. TECHNICAL SPECIFICATIONS

Flow rate, useful prevalence and absorbed power of the circulator

Explains circulator performance characteristics based on flow rate and head for different speed levels.

Operating range

Defines the operational limits for heating and cooling based on air and water temperatures.

4. WARNINGS

Refrigerant gas R 32 safety data sheet extract

Safety information, first aid, firefighting measures, and exposure controls for refrigerant R32.

Attention and dangers

General warnings, prohibitions, symbol meanings, and safety instructions for unit operation.

Prohibitions and warnings for installation

Lists prohibited installation practices and important warnings for qualified personnel.

5. INSTALLATION

Hydraulic system

Details on connecting the hydraulic system, including diagrams and recommendations for a safe setup.

Anti-freeze protection

Explains the unit's built-in anti-freeze function and the necessary settings for operation.

Procedure for water charge and air purge in the hydraulic circuit

Step-by-step guide for filling the hydraulic circuit and removing air to ensure proper circulation.

Electrical System

Information on electrical connections, power supply requirements, and safety precautions.

How to connect the wiring to the terminal

Detailed instructions on connecting wires to the terminal block, including polarity and tightening torques.

6. TYPE OF INSTALLATION

7. THERMAL ADJUSTMENT SMART MT

Parameter lists - Set menu

Details how to access and modify parameters within the "Set" menu for system configuration.

SERVICE SECTION PARAMETER LIST

Comprehensive list of service parameters, including temperatures and analogue inputs.

Signals from Febos Crono Master

Details on signals received from the Febos Crono Master system related to ambient conditions.

Heat Pump operational status - Functions;outputs activation

Explains the operational status and activation of heat pump functions and outputs.

Set Point 2 climate curve activation:

Information on activating Set Point 2 and its associated climate curve for temperature control.

Water temperature settings for compressor frequency adjustment

Parameters for adjusting compressor frequency based on water temperature settings.

DHW Domestic hot water production settings

Parameters for configuring the domestic hot water production, including timings and temperatures.

8. USER SECTION: OPERATION

Heat Pump ON;OFF

Instructions for turning the heat pump on and off using the Febos-Crono Master system.

Operating mode (Heating; Cooling)

How to select heating or cooling mode using the Febos-Crono system based on external commands.

Temperature setting of water Set and climate

Setting target water temperatures and adjusting them via climate curves for heating and cooling.

Modulation of the PdC compressor

How the compressor modulation works across different steps and signals based on operating conditions.

Heating of domestic hot water (DHW)

Instructions for setting up domestic hot water heating using sensors and parameters.

Parallel operation

How the heat pump operates in parallel with an additional generator when thermal load is high.

Alternate operation

How the heat pump operates in alternate mode with a secondary generator based on external temperature.

Frost protection

Information on the unit's frost protection functions and how to manage them via SMART-MT.

Dehumidifier

Configuration and operation modes for the dehumidifier function based on various parameters.

Active alarms

How to view active alarms on the SMART-MT display and access the alarm menu.

9. ALARM CODES ON SMART-MT

Troubleshooting

Common issues and their potential causes or checks for the unit, including storm or interference effects.

Alarm codes on SMART-MT

List of alarm codes displayed on the SMART-MT and their corresponding solutions.

10. CODES AND ALARMS ON PCB DISPLAY

Alarm codes on PCB Display

Error codes displayed on the PCB and their troubleshooting steps, including electrical supply issues.

Alarm codes on PCB Display (continued)

Final PCB error codes for defrost heater, air circulation, gas leakage, and expansion vessel.

11. SERVICE AND MAINTENANCE

14. WIRING DIAGRAMS

Mod. EH0618 DC

Wiring diagram for the EH0618DC model, showing electrical connections to the PCB and components.

15. SCHEDA PRODOTTO; PRODUCT FICHE

emmeti EH1218DC Specifications

General IconGeneral
Heating Capacity12 kW
EER Cooling3.5
RefrigerantR410A
TypeAir to Water
Power Supply220-240V, 50Hz