30794-5-0314 Page 9
In selecting a location for installation, it is necessary to provide
adequate accessibility clearances for servicing and proper opera-
tion.
Locating and Venting the Direct Vent Stove
Clearances: When facing the front of the direct vent stove the
minimum clearances to combustible construction (material) are
the following:
Top of appliance (ceiling) 36" (914.4 mm)
Rear Wall 2" (50.8 mm)
Side Wall 6" (152.4 mm)
Heater Corners (45° angle) to Wall 4" (101.6 mm)
Floor 0" (0 mm)
Installation on Rugs and Tile
This appliance must be installed on a at, solid, continuous surface
(e.g. wood, metal, concrete). This may be the oor, or it may be
raised up on a platform to enhance its visual impact. The continu-
ous surface may be covered with carpeting, vinyl, wood ooring or
other combustible material.
Figure 2
Figure 3
Figure 4
CLEARANCES